Related Experiment Video
Updated: Feb 8, 2026

Dissection and 2-Photon Imaging of Peripheral Lymph Nodes in Mice
Published on: August 23, 2007
An efficient dye-sensitized NIR emissive lanthanide nanomaterial and its application in fluorescence-guided
Qingyun Liu1, Xianmei Zou, Yibing Shi
1Department of Chemistry and The State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedicine Science and Collaborative Innovation Center of Chemistry for Energy Materials, Fudan University, Shanghai, 200433, P. R. China. fyli@fudan.edu.cn fengweifd@fudan.edu.cn.
Abstract:
The luminescence intensity of near-infrared (NIR) emitting lanthanide nanoparticles (LnNPs) is usually limited, owing to their small absorption cross section. Although dye sensitization has been proven to be an effective way to improve the luminescence intensity of LnNPs, the sensitization effect is fairly limited, owing to the simplicity of the sensitizers used and the complexity of the energy transfer process, typically involving three steps. In this study, a more efficient sensitizer (Cy7) was chosen to replace a commonly used one (ICG) and the energy transfer process was also optimized through using Yb3+ ions as emitter ions and Nd3+ ions as intermediate ions. With Cy7 as a sensitizer, the sensitization effect was assessed to be better than with ICG, owing to the higher quantum yield of Cy7. Meanwhile, the Cy7-sensitized NIR lanthanide nanomaterial was proven to be good for deep tissue penetration and low-power excitation bioimaging. Furthermore, the highly-enhanced NIR signal was successfully used in blood vessel imaging and fluorescence-guided peritumoral lymph node dissection in a mouse model.
Related Concept Videos
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Emission Spectra
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Atomic Emission Spectroscopy: Lab

