Related Experiment Video
Updated: Feb 8, 2026

Failure of Cleaning Verification in Pharmaceutical Industry Due to Uncleanliness of Stainless Steel Surface
Published on: August 11, 2017
Specificity of process analytical tools in the monitoring of multicomponent pharmaceutical powders
Pedro Durão1, Clémence Fauteux-Lefebvre2, Jean-Maxime Guay3
1a Department of Chemical & Biotechnological Engineering , Pfizer Industrial Research Chair, Université de Sherbrooke , Sherbrooke , Québec , Canada.
Abstract:
The application of Process Analytical Technologies in pharmaceutical manufacturing has been the subject of many studies. Active pharmaceutical ingredient monitoring in real time throughout the manufacturing process is commonly the target of many such implementations. The tools in place must be sensitive to, and selective of, the parameter(s) to be monitored, i.e. in the case of component quantification, they must respond to the component in question and be robust against all others. In this study, four different ingredients (riboflavin, ferrous fumarate, ginseng, and ascorbic acid) in a multi-component blend were monitored by three different tools (near infrared spectroscopy, laser-induced fluorescence and red-green-blue camera) using a full factorial design. The goal was to develop efficient and robust concentration-reading/prediction models able to assess and monitor component interference. Despite relatively high complexity of the blend studied, the three tools demonstrated reasonable specificity for the tracked ingredients (and showed advantages when combined), taking into account larger acceptance criteria typical of dietary products. In certain cases, some interference might lead to biased predictions, highlighting the importance of good calibration. The tools tested and the methodology proposed has divulged their potential in monitoring these components, despite the complexity of the 31-component blend.
More Related Videos
Related Concept Videos
Pharmaceutical Equivalents
Development of Analytical Methods
Analyte Adsorption and Distribution
Jung's Analytical Theory
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...

