Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
A hybrid simulation framework for computer simulation and modelling studies of grating-based x-ray phase-contrast
J Vignero1, N W Marshall, K Bliznakova
1Department of Imaging and Pathology, KULeuven, Oude Markt 13 bus 5005, Leuven, Belgium.
Abstract:
Clinical studies performed using computer simulation are inexpensive, flexible methods that can be used to study aspects of a proposed imaging technique prior to a full clinical study. Typically, lesions are simulated into (experimental) data to assess the clinical potential of new methods or algorithms. In grating-based phase-contrast imaging (GB-PCI), full wave simulations are, however, computationally expensive due to the high periodicity of the gratings and therefore not practically applicable when large data sets are required. This work describes the development of a hybrid modelling platform that combines analytical and empirical input data for a more rapid simulation of GB-PCI images with little loss of accuracy. Instead of an explicit implementation of grating details, measured summary metrics (i.e. visibility, flux, noise power spectra, presampling modulation transfer function) are applied in order to generate transmission and differential phase images with large fields of view. Realistic transmission and differential phase images were obtained with good quantitative accuracy. The different steps of the simulation framework, as well as the methods to measure the summary metrics, are discussed in detail such that the technique can be easily customized for a given system. The platform offers a fast, accurate alternative to full wave simulations when the focus switches from grating/system design and set up to the generation of GB-PCI images for an established system.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Hybrid Zones
Hybridization of Atomic Orbitals I