Background:
Recently, the use of transcutaneous bone conduction implants (BCIs) has been increased. However, scarce data about BCI hearing recovery in noise conditions have been reported.
Objectives:
To investigate the audiological benefits obtained with transcutaneous BCI-Sophono Alpha System in noise conditions. To evaluate post-implantation clinical outcomes and patient satisfaction levels.
Materials And Methods:
Fourteen patients suffering from conductive or mixed hearing loss implanted with the Sophono Alpha System were evaluated. Patients underwent physical examination, free-field pure-tone and speech audiometry both in unaided and aided conditions. The matrix sentence test was employed with fixed noise at 65 dB, and with a fluctuating primary signal, in three different conditions of noise presentations (S0/N0, S0/Ncontra, S0/Nipsi).
Results:
Hearing gain, expressed as the difference between pre-implant AC and post-implant SAS free field, was on average 26.7 dB. The unaided speech recognition score in quiet conditions had a mean value of 64.6%, and improved after SAS implantation, achieving mean values of 98.2%. SRT50 with the matrix sentence test improved in all three conditions of noise presentation.
Conclusions:
Sophono Alpha System devices represent a valid treatment option for hearing rehabilitation of patients with conductive or mixed hearing loss. The audiological results regarding hearing gain in noise conditions were good.
More Related Videos
06:27Simple Surgical Induction of Conductive Hearing Loss with Verification Using Otoscope Visualization and Behavioral Clap Startle Response in Rat
Published on: October 26, 2019
04:32Sound Source Localization Testing in Single-sided Deafness Following Bone Conduction Intervention
Published on: December 20, 2024
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduct Disorder
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
Theory of Metallic Conduction
In this theory, Newton's second law of motion is used to determine the acceleration of an electron in the presence of an applied electric field. Then, its velocity is expressed via this acceleration.
An electron moves through the crystal, containing positive ions,...