Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Comparison between Wavefront-optimized and corneal Wavefront-guided Transepithelial photorefractive keratectomy in
Ikhyun Jun1,2, David Sung Yong Kang3, Samuel Arba-Mosquera4
1The Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemungu, Seoul, 03722, South Korea.
Background:
To compare the clinical outcomes of wavefront-optimized (WFO) transepithelial photorefractive keratectomy (trans-PRK) and corneal wavefront-guided (CWFG) trans-PRK for myopic eyes with moderate to high astigmatism.
Methods:
One hundred ninety-six eyes (196 patients) with moderate to high astigmatism (≥ 1.75 D) treated with WFO or CWFG trans-PRK (101 and 95 eyes, respectively) were retrospectively registered. Safety, efficacy, predictability, vector analysis, and corneal aberrations were compared between groups preoperatively and at 6 months postoperatively.
Results:
At postoperative 6 months, the mean logMAR uncorrected distance visual acuity was similar in the WFO (- 0.07 ± 0.08) and CWFG (- 0.07 ± 0.07) groups. Safety, efficacy, and predictability of refractive and visual outcomes were also similar. The correction indices were 1.02 ± 0.14 and 1.03 ± 0.13 in the WFO and CWFG groups, respectively, with no significant difference. The absolute values of the angle of error were significantly higher in the WFO group (2.28 ± 2.44 vs. 1.40 ± 1.40; P = 0.002). Corneal total root mean square higher-order aberrations and corneal spherical aberrations increased postoperatively in both groups; however, the change was smaller in the CWFG group. Corneal coma showed a significant increase postoperatively only in the WFO group.
Conclusions:
WFO and CWFG trans-PRK are safe and effective for correcting moderate to high astigmatism. However, CWFG trans-PRK provides a more predictable astigmatism correction axis and fewer induced corneal aberrations.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Optimal Foraging
Optimization Problems
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...