Rationale:
We report new K-Ar isochron data for two ~380 Ma basaltic rocks, using an updated version of the Potassium-Argon Laser Experiment (KArLE), which is being developed for future in situ dating of planetary materials. These basalts have K contents comparable with those of lunar KREEP basalts or igneous lithologies found by Mars rovers, whereas previous proof-of-concept studies focused primarily on more K-rich rocks. We aim to measure these analogous samples to show the advancing capability of in situ K-Ar geochronology.
Methods:
Combining laser-induced breakdown spectroscopy (LIBS), mass spectrometry (MS), and microscopic analyses, we measured the abundance of K and 40 Ar from 23 spots on the basalt samples. We then constructed K-Ar isochron plots from these rocks. The breadboard instrument consists of flight-equivalent devices including a 30-mJ Nd:YAG laser and a quadrupole mass spectrometer.
Results:
Despite much lower K abundances than in previous studies, the isochron slopes yielded 380 ± 44 Ma and 398 ± 50 Ma for 380.7-Ma and 373.5-Ma rocks, respectively, indicating that accuracy better than 25 Ma (<7%) is achievable with our instrument. The isochron intercepts both yielded trapped 40 Ar approximately 1 × 10-6 cm3 STP/g.
Conclusions:
Our experimental results demonstrate that accurate and precise measurements are possible using the KArLE approach on basaltic rocks, which are ubiquitous on planetary surfaces, and are useful in addressing a wide range of questions in planetary science.
Related Concept Videos
Radioactive Decay and Radiometric Dating
Regulation of Sodium and Potassium
Sodium Regulation
Sodium ions make up approximately 90% of extracellular cations, with a normal blood plasma concentration of 136–148 mEq/L. A decrease in blood volume and pressure triggers the release of renin from granular cells in the juxtaglomerular complex (JGC), primarily...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers
Uncertainty in Measurement: Reading Instruments