Related Experiment Video
Updated: Feb 8, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Evaluation of leak pressure and closure time for double-layer esophagotomy closure with an interrupted or a
Abstract:
OBJECTIVE To compare the leak pressure and amount of time required to perform closure for 2 double-layer esophagotomy closure techniques. SAMPLE 28 intrathoracic esophageal segments harvested from 38 porcine cadavers. PROCEDURES Longitudinal 3-cm esophagotomy incisions made in porcine cadaveric esophagi were closed with 2 double-layer closure techniques. Fifteen incisions were closed with a simple interrupted pattern, and 13 incisions were closed with a simple continuous pattern. Leak pressure, bursting wall tension, and closure time were compared between suture patterns by use of a t test or Mann-Whitney rank sum test. RESULTS Median leak pressures differed significantly between segments closed with the simple interrupted pattern (16.0 mm Hg; range, 5.4 to 54.9 mm Hg) and the simple continuous pattern (38.7 mm Hg; range, 11.3 to 81.9 mm Hg). Median bursting wall tension differed significantly between the simple interrupted pattern (0.63 × 105 dynes/cm; range, 0.16 × 105 dynes/cm to 2.89 × 105 dynes/cm) and the simple continuous pattern (1.79 × 105 dynes/cm; range, 0.44 × 105 dynes/cm to 4.70 × 105 dynes/cm). Mean ± SD closure time differed significantly between the simple interrupted pattern (19.2 ± 2.0 minutes) and the simple continuous pattern (14.7 ± 1.5 minutes). CONCLUSIONS AND CLINICAL RELEVANCE In the study reported here, double-layer simple continuous closure resulted in a higher median postoperative leak pressure and higher median postoperative bursting wall tension and could be performed more rapidly than the double-layer simple interrupted closure on these porcine cadaveric specimens.
More Related Videos
09:41Surgical Closure of Equine Abdomen, Prevention, and Management of Incisional Complications
Published on: May 10, 2024
20:33A Case Series of Successful Abdominal Closure Utilizing a Novel Technique Combining a Mechanical Closure System with a Biologic Xenograft that Accelerates Wound Healing
Published on: July 4, 2019
Related Concept Videos
Angle Closure Glaucoma: Treatment
Basic Continuous Time Signals
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
Sampling Continuous Time Signal
In the...
Continuous -time Fourier Transform
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...