Related Experiment Video
Updated: Feb 8, 2026

In vivo 19F MRI for Cell Tracking
Published on: November 25, 2013
Ex Vivo Mercury Release from Dental Amalgam after 7.0-T and 1.5-T MRI
Selmi Yilmaz1, M Zahit Adisen1
1From the Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Akdeniz University, P.K. 10 Dumlupinar Bulvari Kampus, 07058 Konyaalti/Antalya, Turkey (S.Y.); and Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Kirikkale University, Kirikkale, Turkey (M.Z.A.).
Abstract:
Purpose To evaluate ex vivo mercury release from dental amalgam after 7.0-T and 1.5-T MRI. Materials and Methods The authors evaluated 60 caries-free molar or premolar teeth that had been extracted for clinical indications. Two-sided cavities were opened in each tooth and amalgam fillings applied. After 9 days, two groups of 20 randomly selected teeth were placed in 20 mL of artificial saliva immediately followed by 20 minutes of MRI exposure at 1.5 or 7.0 T. A control group of teeth was placed in artificial saliva without undergoing MRI exposure. The teeth were removed from the artificial saliva 24 hours later, and the saliva was analyzed for mercury content by using inductively coupled plasma mass spectrometry. One-way analysis of variance was used to compare the mean mercury values among the three independent groups, and the Tukey test was used for multiple comparisons of the mean values. Results The mean mercury content of the artificial saliva was 673 μg/L ± 179 in the 7.0-T MRI group, 172 μg/L ± 60 in the 1.5-T MRI group, and 141 μg/L ± 152 in the control group. The mercury content in the 7.0-T group was greater than that in both the 1.5-T group (P < .001; 95% confidence interval: 368 μg/L, 633 μg/L) and the control group (P < .001; 95% confidence interval: 416 μg/L, 648 μg/L). There was no statistically significant difference in mercury content between the 1.5-T and control groups (P = .84; 95% confidence interval: -164 μg/L, 110 μg/L). Conclusion In an ex vivo setting, mercury was released from amalgam fillings after exposure to 7.0-T MRI but not 1.5-T MRI.
Related Concept Videos
Energy-releasing Steps of Glycolysis
The first energy-releasing step—the 6th step of glycolysis...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
ATP Energy Storage and Release
One example of energy coupling using ATP involves a...
Drugs Affecting Neurotransmitter Release or Uptake
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
In Vitro Drug Release Testing: Overview, Development and Validation