Movement Velocity as a Measure of Level of Effort During Resistance Exercise
Ricardo Morán-Navarro1,2, Alejandro Martínez-Cava1, Luis Sánchez-Medina3
1Human Performance and Sports Science Laboratory, University of Murcia, Murcia, Spain.
Abstract:
Morán-Navarro, R, Martínez-Cava, A, Sánchez-Medina, L, Mora-Rodríguez, R, González-Badillo, JJ, and Pallarés, JG. Movement velocity as a measure of level of effort during resistance exercise. J Strength Cond Res 33(6): 1496-1504, 2019-This study analyzed whether the loss of repetition velocity during a resistance exercise set was a reliable indicator of the number of repetitions left in reserve. After the assessment of one-repetition (1RM) strength and full load-velocity relationship, 30 men were divided into 3 groups according to their 1RM strength per body mass: novice, well trained, and highly trained. On 2 separate occasions and in random order, subjects performed tests of maximal number of repetitions to failure against loads of 65, 75, and 85% 1RM in 4 exercises: bench press, full squat, prone bench pull, and shoulder press. For each exercise, and regardless of the load being used, the absolute velocities associated with stopping a set before failure, leaving a certain number of repetitions (2, 4, 6, or 8) in reserve, were very similar and showed a high reliability (coefficient of variation [CV] 4.4-8.0%). No significant differences in these stopping velocities were observed for any resistance training exercise analyzed between the novice, well trained and highly trained groups. These results indicate that by monitoring repetition velocity one can estimate with high accuracy the proximity of muscle failure and, therefore, to more objectively quantify the level of effort and fatigue being incurred during resistance training. This method emerges as a substantial improvement over the use of perceived exertion to gauge the number of repetitions left in reserve.
More Related Videos
04:53Measuring Exercise Levels in Drosophila melanogaster Using the Rotating Exercise Quantification System REQS
Published on: May 27, 2018
06:28A Chronic High-Intensity Interval Training and Diet-Induced Obesity Model to Maximize Exercise Effort and Induce Physiologic Changes in Rats
Published on: April 28, 2023
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...
Average Velocity
Instantaneous Velocity - II
