Ye's Swing Technique for Small-incision Lenticule Extraction Surgery
Published on: June 27, 2025
Predictability of the Achieved Lenticule Thickness in Small Incision Lenticule Extraction for Myopia Correction
Jiaqi Zhou1, Yan Zhang, Meiyan Li
1Department of Ophthalmology (J.Z., M.L., L.S., X.Z.), Key Lab of Myopia, Ministry of Health, EYE & ENT Hospital of Fudan University, Shanghai, China; and Department of Ophthalmology (Y.Z.), Second Hospital of Jilin University, Changchun, China.
Purpose:
To investigate the predictability of the achieved lenticule thickness in small incision lenticule extraction (SMILE) for the correction of myopia.
Methods:
In this prospective study, a total of 80 eyes of 45 patients who underwent the SMILE procedure were included. A Scheimpflug camera was used to measure the preoperative and postoperative corneal topography. Achieved lenticule thicknesses at the pupil center and corneal vertex were calculated by subtracting the postoperative corneal thickness at the pupil center and corneal vertex from preoperative corresponding values. Predictability between the achieved and VisuMax readout at different locations (the pupil center and corneal vertex) and postoperative visits (postoperative day 1 and 6 months) were evaluated using a general linear model.
Results:
Achieved lenticule thickness at the pupil center and corneal vertex showed good correlation at both postoperative day 1 (pupil center: r=0.914, corneal vertex: r=0.903) and 6 months (pupil center: r=0.886, corneal vertex: r=0.866). The achieved lenticule thickness at postoperative day 1 was 8.5-μm thinner at the pupil center and 9.6-μm thinner at the corneal vertex than the VisuMax readout.
Conclusions:
This study suggests that the predictability between the achieved and VisuMax readout is favorable. The lenticule thickness at the pupil center is closer to the VisuMax readout than corneal vertex.
Related Concept Videos
Distance Corrections
Power Factor Correction
Predicting Molecular Geometry
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
NMR Spectrometers: Resolution and Error Correction
End Point Prediction: Gran Plot
For potentiometric titration, the Gran plot is created by plotting...