Related Experiment Video
Updated: Feb 8, 2026

Author Spotlight: Advancing Syphilis Research — Innovations in Treponema pallidum Cultivation and Genetic Engineering
Published on: January 24, 2025
Challenges of Rapid Plasma Reagin Interpretation in Syphilis Screening in Uganda: Variability in Nontreponemal
Matthew M Hamill, Kimeze J Mbazira1, Agnes N Kiragga1
1Infectious Disease Institute, Kampala, Uganda.
Background:
Syphilis is a cause of morbidity and mortality and is of particular concern in pregnancy in low-income countries because of the risks associated with maternal-fetal transmission. Ugandan national guidelines recommend a nontreponemal rapid plasma reagin (RPR) followed by treponemal testing for diagnosis of syphilis. The RPR test confirms a reactive specific treponemal test, or confirms serological "cure" with a 4-fold dilutional decrease; RPR is beset with technical and biological limitations, making accurate diagnosis and appropriate treatment problematic. The aim of this analysis was to compare performance of RPR testing in different laboratories.
Methods:
Stored, freeze-thawed sera from 215 participants were additionally tested for RPR and dilutional titer in 2 different reference laboratories. Discrepant results were tested at a third reference laboratory which served as a tie-breaker. Equivalence in RPR titer was defined as within 2-fold or less. All patients with reactive rapid tests were treated as per Ugandan National Guidelines.
Results:
Of 215 sera, 97 (45.1%) were RPR reactive in clinic laboratory A, 81 (37.7%) and 65 (30.2%) were RPR reactive in laboratories B and C, respectively. All reported positive in laboratory C were positive in laboratory B. Discrepant results were tested in laboratory D. χ Test was highly significant (P = <0.001) for difference between each dyad of laboratories (A and B, A and C, and B and C) RPR results. There were significant differences between RPR titers by paired t test and Wilcox rank test (P = <0.001); with up to a 3-fold difference between laboratories. Two one-sided test approach demonstrated nonequivalence. Agreement between laboratories B-D, and C-D: 48 (98.0%) of 49 and 34 (69.4%) of 49, respectively (P = <0.001). Laboratories B and D showed no significant difference and had equivalent RPR titers. Laboratories C and D had different titers (P = <0.001) and were not equivalent.
Conclusions:
We found significant interlaboratory discrepant RPR results. A 3-fold difference in results is likely to be clinically significant and could result in undertreatment or overtreatment. These data demonstrate a key limitation of the RPR test and underline the urgent need for a more reproducible quantitative test than the current RPR for diagnosing and determining cure of syphilis.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Interpreting R Charts
An R chart plots the range of subsets of measurements collected from a process. Each point on the chart represents the range—defined as the difference between the maximum and minimum...
Interpreting Run Charts
Graphs of Equations in Two Variables
Variables Affecting Phosphorescence and Fluorescence