Short-course High-dose Liposomal Amphotericin B for Human Immunodeficiency Virus-associated Cryptococcal Meningitis:

Joseph N Jarvis1,2,3,4, Tshepo B Leeme1, Mooketsi Molefi4

  • 1Botswana-University of Pennsylvania Partnership, Gaborone.

Abstract

Related Concept Videos

Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
570
Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
574
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
718
Cranial and Spinal Meninges01:19

Cranial and Spinal Meninges

The cranial and spinal meninges are complex protective structures surrounding the central nervous system (CNS), consisting of the brain and spinal cord. These meninges consist of the dura mater, the arachnoid mater, and the pia mater. They protect the CNS, provide structural support, and aid in circulating cerebrospinal fluid (CSF).
Cranial Meninges
These meningeal layers cover the cranium. The dura mater is the outermost layer of cranial meninges. It is a thick and durable membrane of dense...
4.1K
Immunodeficiency Diseases01:25

Immunodeficiency Diseases

Immunodeficiency disorders are conditions in which the immune system's ability to fight infectious disease and cancer is compromised or entirely absent. The immune system comprises a complex network of cells, tissues, and organs that work together to protect the body from potentially harmful invaders. When this system is deficient or not functioning properly, it leaves the body susceptible to infections, diseases, or other complications.
There are three main causes of immunodeficiency...
2.4K
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
477