Related Experiment Video
Updated: Feb 8, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
A Validated Routine Method for Butyltin Determination in Seafood by Gas Chromatography Inductively Coupled Plasma
Stig Valdersnes1, Berit Solli1, Veronika Sele1
1Institute of Marine Research, PO Box 1870 Nordnes, N-5817 Bergen, Norway.
Abstract:
Organotin compounds are anthropogenic metal species with multiple uses as pesticides, preservatives, antifouling agents, biocides, and catalysts. Butyltins are the main organotin compounds found in biota, and the highest levels are found in marine foodstuffs. In this paper, we present the figures of merit for an in-house validated method for routine analysis of butyltins in seafood using GC inductively coupled plasma isotope dilution MS. The working range of the method spanned several orders of magnitude from 3.3-1013, 2.4-785, and 0.3-900 ng Sn/g dry weight for monobutyltin (MBT), dibutyltin (DBT), and tributyltin (TBT), respectively. The trueness of the method was evaluated by analyzing Certified Reference Materials (CRMs) ERM CRM 477 (Mussel Tissue) and NIES CRM 15 (Scallop). Recoveries, with RSD % in parentheses, were 78 (±14), 80 (±6), and 88% (±8%) for MBT, DBT, and TBT in ERM CRM 477 and 96% (±5%) for TBT in NIES CRM 15. Good agreements were found between experimental uncertainties and uncertainties predicted for single-laboratory validated methods calculated from the maximum standard measurement uncertainty function. The method has proven to be robust, and the wide range of seafood validated ensures that the method is applicable for measuring butyltins in marine tissue.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Isotope Effect
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....