Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Nuclear Stability03:18

Nuclear Stability

23.3K
Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively charged protons together...
23.3K
RNA Stability01:53

RNA Stability

35.8K
Intact DNA strands can be found in fossils, while scientists sometimes struggle to keep RNA intact under laboratory conditions. The structural variations between RNA and DNA underlie the differences in their stability and longevity. Because DNA is double-stranded, it is inherently more stable. The single-stranded structure of RNA is less stable but also more flexible and can form weak internal bonds. Additionally, most RNAs in the cell are relatively short, while DNA can be up to 250 million...
35.8K
Stability01:28

Stability

421
The time response of a linear time-invariant (LTI) system can be divided into transient and steady-state responses. The transient response represents the system's initial reaction to a change in input and diminishes to zero over time. In contrast, the steady-state response is the behavior that persists after the transient effects have faded.
The stability of an LTI system is determined by the roots of its characteristic equation, known as poles. A system is stable if it produces a bounded...
421
Optimal Foraging00:48

Optimal Foraging

13.9K
How animals obtain and eat their food is called foraging behavior. Foraging can include searching for plants and hunting for prey and depends on the species and environment.
13.9K
mRNA Stability and Gene Expression02:51

mRNA Stability and Gene Expression

6.7K
The structure and stability of mRNA molecules regulates gene expression, as mRNAs are a key step in the pathway from gene to protein. In eukaryotes, the half-life of mRNA varies from a few minutes up to several days. mRNA stability is essential in growth and development. The absence of the proteins regulating its stability, such as tristetraprolin in mice, can cause systemic issues, including bone marrow overgrowth, inflammation, and autoimmunity.
Cis-acting Elements involved in mRNA stability
6.7K
Optimization Problems01:26

Optimization Problems

78
Optimization problems often involve identifying maximum or minimum values under specific constraints. A well-known example is determining the longest horizontal pipe that can be moved around a right-angled corner, where a 3-meter-wide hallway meets a 2-meter-wide hallway. This scenario, common in architectural design and industrial transport, can be understood conceptually through geometric and trigonometric reasoning.To visualize the problem, consider the pipe as a straight line that touches...
78

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Artificial neural networks for predicting ground reaction forces, feet centers of pressure, spine loads, and trunk muscle forces during load-handling activities.

Journal of biomechanics·2026
Same author

Effect of pedicle screw misplacement on the pull-out strength using personalized finite element modeling.

Computers in biology and medicine·2024
Same author

Design, fabrication, and evaluation of single- and multi-level 3D-printed non-covering cervical spinal fusion surgery templates.

Frontiers in bioengineering and biotechnology·2024
Same author

Evaluation of ground reaction forces and centers of pressure predicted by AnyBody Modeling System during load reaching/handling activities and effects of the prediction errors on model-estimated spinal loads.

Journal of biomechanics·2024
Same author

Effect of obesity on spinal loads during load-reaching activities: A subject- and kinematics-specific musculoskeletal modeling approach.

Journal of biomechanics·2023
Same author

FloodIMG: Flood image DataBase system.

Data in brief·2023
Same journal

Development and experimental characterization of a cadaveric stance simulator for residual limb biomechanics.

Medical engineering & physics·2026
Same journal

Rapid personalized computational modeling of the wrist.

Medical engineering & physics·2026
Same journal

SHAP-enabled explainable AI framework for clinical interpretation of valvular heart diseases via digital acoustic features.

Medical engineering & physics·2026
Same journal

Three-dimensional motion analysis of a total wrist prosthesis during the dart-throwing motion: a cadaveric study.

Medical engineering & physics·2026
Same journal

Patient-specific left ventricular hypertrophy under severe hypertension: mechanistic insights from Hill-type computational simulations.

Medical engineering & physics·2026
Same journal

Enabling laboratory-based personalization of musculoskeletal spine models: a standardized rail-guided ultrasound method.

Medical engineering & physics·2026
See all related articles

Related Experiment Video

Updated: Feb 8, 2026

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
06:24

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement

Published on: May 11, 2020

9.4K

A novel stability-based EMG-assisted optimization method for the spine.

S Samadi1, N Arjmand1

  • 1Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.

Medical Engineering & Physics
|June 28, 2018
PubMed
Summary
This summary is machine-generated.

A new stability-based electromyography-assisted optimization (SEMG) method improves trunk muscle force and spinal load calculations. This approach enhances accuracy for clinical and ergonomic applications by incorporating stability requirements into musculoskeletal spine models.

Keywords:
Biomechanical modelElectromyography (EMG)ForcesMuscle stiffnessSpineStability

More Related Videos

Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF
08:34

Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF

Published on: October 17, 2025

578
Extraction of the EPP Component from the Surface EMG
07:16

Extraction of the EPP Component from the Surface EMG

Published on: December 16, 2009

12.9K

Related Experiment Videos

Last Updated: Feb 8, 2026

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
06:24

A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement

Published on: May 11, 2020

9.4K
Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF
08:34

Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF

Published on: October 17, 2025

578
Extraction of the EPP Component from the Surface EMG
07:16

Extraction of the EPP Component from the Surface EMG

Published on: December 16, 2009

12.9K

Area of Science:

  • Biomechanics
  • Musculoskeletal Modeling
  • Spinal Load Analysis

Background:

  • Traditional electromyography-assisted optimization (TEMG) models calculate trunk muscle forces and spinal loads using moment equilibrium.
  • These models often fail to meet stability requirements due to simplifications in EMG processing and muscle force relationships.

Purpose of the Study:

  • To develop and validate a novel stability-based EMG-assisted optimization (SEMG) method for improved estimation of trunk muscle forces and spinal loads.
  • To compare SEMG predictions with traditional TEMG models and experimental data.

Main Methods:

  • A musculoskeletal spine model was developed incorporating stability constraints, defined by positive semi-definite second-order partial derivatives of potential energy.
  • Fifteen static tasks were simulated in various postures and with external loads.
  • Trunk muscle forces and spinal loads were estimated using the SEMG method.

Main Results:

  • The SEMG model predicted generally larger global and local trunk muscle forces and slightly larger spinal loads compared to the TEMG model.
  • Differences in predictions were dependent on the muscle stiffness coefficient used in the SEMG model.
  • SEMG-predicted L4-L5 intradiscal pressures showed satisfactory agreement with measured data.

Conclusions:

  • The SEMG method provides a more robust approach to estimating trunk muscle forces and spinal loads by integrating stability requirements.
  • This enhanced accuracy has significant implications for designing effective clinical treatments and ergonomic interventions.
  • The SEMG model demonstrates potential for more realistic biomechanical simulations of the spine.