Neonatal Contrast Sensitivity and Visual Acuity: Basic Psychophysics
Angela M Brown1, Faustina Ottie Opoku1, Michael R Stenger2
1The Ohio State University, College of Optometry, Columbus, OH, USA.
Purpose:
This research was prospectively designed to determine whether a 0.083 cycles per degree (cy/deg) (20/7200) square-wave stimulus is a good choice for clinical measurement of newborn infants' contrast sensitivity and whether the contrast sensitivity function (CSF) of the newborn infant is band-pass. The results were retrospectively analyzed to determine whether the method of constant stimuli (MCS) and the descending method of limits (dLIM) yielded similar results.
Methods:
In across-subjects experimental designs, a pilot experiment used MCS (N = 47 visual acuity; N = 38 contrast sensitivity at 0.083 cy/deg), and a main experiment used dLIM (N = 22 visual acuity; N = 22 contrast sensitivity at 0.083 cy/deg; N = 21 at 0.301 cy/deg) to measure visual function in healthy newborn infants. Three candidate CSFs estimated maximum neonatal contrast sensitivity. MCS and dLIM psychometric functions were compared while taking the stimulus presentation protocols into account.
Results:
The band-pass CSF fit the data best, with a peak sensitivity near 0.31 at 0.22 cy/deg. However, the 0.083 cy/deg square-wave stimulus underestimated the best performance of newborn infants by less than 0.15 log10 units. MCS and dLIM data agreed well when the stimulus presentation contingencies were taken into account.
Conclusions:
Newborn contrast sensitivity is well measured using a 0.083 cy/deg square-wave target, regardless of which CSF shape is correct. MCS and dLIM yield wholly comparable results, with no evidence to suggest effects of other factors such as infant inattention or examiner impatience.
Translational Relevance:
These measurements open the way for clinical behavioral measurement of infant visual acuity and contrast sensitivity in the neonatal period.
Related Concept Videos
Energy Basics
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Basicity of Aliphatic Amines
To measure the basicity of amines, two conventions are generally used. The first defines Kb as the basicity constant for the deprotonation reaction of water by the amine, as presented in Figure 1. Conventionally, lower Kb indicates higher...
Basic Operations on Signals
Time Reversal mirrors a continuous-time signal about the vertical axis at t=0. This is achieved by substituting t with −t. For example, if a signal x(t) is considered, the time-reversed signal is x(−t). This operation can be graphically represented, showing the mirrored signal.
VSEPR Theory and the Basic Shapes
Basic Concept
Length, which measures the distance traveled by an object, is a fundamental concept in engineering mechanics. We use coordinates relative to a reference point to describe the distance. Length not only helps to describe the...