MRI and PET in Mouse Models of Myocardial Infarction
Published on: December 19, 2013
Automatic calculation of myocardial external efficiency using a single 11C-acetate PET scan
Hendrik J Harms1, Nils Henrik S Hansson2, Tanja Kero3
1Department of Nuclear Medicine, & PET Center, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.
Myocardial external efficiency (MEE) can be accurately measured using a single 11C-acetate PET scan. This method shows reduced MEE in valvular heart disease, reflecting disease severity.
Area of Science:
- Cardiology
- Nuclear Medicine
- Biomedical Engineering
Background:
- Myocardial external efficiency (MEE) quantifies cardiac work relative to energy consumed.
- Current methods for MEE assessment are complex and often require ECG-gating.
- A novel, automated method using 11C-acetate PET without ECG-gating was developed.
Purpose of the Study:
- To develop and validate a fully automated method for estimating MEE using a single 11C-acetate PET scan.
- To assess MEE in healthy individuals and patients with aortic valve stenosis (AVS) and mitral valve regurgitation (MVR).
- To evaluate the association between MEE and clinical parameters of valvular heart disease.
Main Methods:
- A dual-center study included 10 healthy controls, 34 AVS patients, and 20 MVR patients.
- Metabolic rate of oxygen consumption (MVO2) was calculated from 11C-acetate kinetics.
- Forward cardiac output (FCO) and left ventricular mass (LVM) were automatically derived from dynamic PET imaging.
Main Results:
- The automated PET-derived MEE (MEE_PET) showed high correlation (r=0.85) with MEE derived from cardiac magnetic resonance (MEE_PET-CMR).
- MEE_PET was significantly lower in AVS (17.2%) and MVR (18.0%) patients compared to controls (23.6%).
- MEE_PET strongly correlated with NYHA class and the severity of valvular dysfunction.
Conclusions:
- A single 11C-acetate PET scan provides accurate and automated MEE measurements across different scanners.
- Automated MEE assessment using PET may offer an unbiased evaluation of the heart's response to valvular disease.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Automatic Processing and Automatic Social Behavior
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Leaky Scanning
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation: