Related Experiment Video
Updated: Feb 8, 2026

Label-free Isolation and Enrichment of Cells Through Contactless Dielectrophoresis
Published on: September 3, 2013
Screening of seized cocaine samples using electrophoresis microchips with integrated contactless conductivity
Roger Cardoso Moreira1, Brenda M C Costa2, Mariana C Marra2
1Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, Brazil.
Abstract:
This study describes the development of a new analytical method for the separation and detection of cocaine (COC) and its adulterants, or cutting agents, using microchip electrophoresis (ME) devices coupled with capacitively coupled contactless conductivity detection (C4 D). All the experiments were carried out using a glass commercial ME device containing two pairs of integrated sensing electrodes. The running buffer composed of 20 mmol/L amino-2-(hydroxymethyl) propane-1,3-diol and 10 mmol/L 3,4-dimethoxycinnamic acid provided the best separation conditions for COC and its adulterants with baseline resolution (R > 1.6), separation efficiencies ranging from (2.9 ± 0.1) to (3.2 ± 0.2) × 105 plates/m, and estimated LOD values between 40 and 150 μmol/L. The quantification of COC was successfully performed in four samples seized by the Brazilian Federal Police Department and all predicted values agree with values estimated by the reference method. Some other interfering species were detected in the seized samples during the screening procedure on ME-C4 D devices. While lidocaine was detected in sample 3, the presence of levamisole was observed in samples 2 and 4. However, their concentrations were estimated to be below the LOQ. ME-C4 D devices have proved to be quite efficient for the identification and quantification of COC with errors lower than 10% when compared to the data obtained by a reference method. The approach herein reported offers great potential to be used for on-site COC screening in seized samples.
Related Concept Videos
CNS Stimulants: Cocaine, Amphetamines and Cannabinoids
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduct Disorder
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...

