Elucidation of chromatographic peak shifts in complex samples using a chemometrical approach

Pedro F M Sousa1, Angela de Waard2, K Magnus Åberg2

  • 1Unit for Analytical Chemistry, Department of Environmental and Analytical Chemistry, Stockholm University, SE-106 91, Stockholm, Sweden. pedro.sousa@aces.su.se.

Related Concept Videos

Chromatographic Resolution01:15

Chromatographic Resolution

In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
2.2K
Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
4.0K
Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
4.0K
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
1.0K
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
1.8K
IR Spectrum Peak Intensity: Amount of IR-Active Bonds00:55

IR Spectrum Peak Intensity: Amount of IR-Active Bonds

When infrared radiation is passed through a molecule, absorption occurs if the molecule's vibration leads to a substantial change in its bond dipole moment. Transitions between vibrational energy levels, typically corresponding to infrared frequencies (4000–400 cm−1), allow absorption if the vibration significantly alters the dipole moment, making the molecule infrared active. The molecular bonds have different stretching and bending vibrations, resulting in various peaks with...
1.1K