Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression
Torsten Diekhoff1, Nils Engelhard2, Michael Fuchs3
1Department of Radiology, Charité - Universitätsmedizin Berlin, Campus Mitte, Humboldt-Universität zu Berlin, Freie Universität Berlin, Charitéplatz 1, 10117, Berlin, Germany. torsten.diekhoff@charite.de.
Objectives:
To evaluate the diagnostic accuracy of single-source dual-energy computed tomography (DECT) for the detection of bone marrow oedema (BME) in patients with vertebral compression fractures.
Methods:
Patients over 50 years of age with radiographically suspected vertebral compression fracture of the thoracic or lumbar spine were prospectively enrolled. All patients underwent DECT with sequential acquisition of 80 and 135 kVp datasets on a 320-row detector CT scanner and 1.5-Tesla magnetic resonance imaging (MRI) including T1-weighted and short-tau inversion recovery (STIR) sequences. Virtual non-calcium (VNCa) images were reconstructed using a three-material decomposition algorithm. Vertebrae with height loss in CT were scored for the presence of BME in both MRI and DECT and used to determine signal- and contrast-to-noise ratios (SNR and CNR). Contingency analysis using MRI as standard of reference and Fleiss's kappa were calculated. IRB approval was obtained.
Results:
In total 192 vertebral compression fractures in 70 patients (23 men, 47 women; mean age 70.7 years (SD 9.8)) were included in our analysis. DECT showed a reader-dependent sensitivity of 72% and specificity of 70% for BME. Fleiss's kappa was .40 for DECT and .58 for MRI. T1-weighted images had significantly better SNR and CNR compared to STIR, CT, and VNCa (p < .0001); however, there was no difference between STIR and VNCa.
Conclusions:
VNCa images depict BME with adequate sensitivity and specificity and can be acquired on a single-source system. Image quality is adequate but trained readers are needed for image interpretation.
Key Points:
• Dual-energy CT in a single-source technique can help to detect bone marrow oedema in patients with vertebral compression fractures. • However, given the inferior inter-rater reliability and limited specificity compared to MRI, experienced readers are needed for image interpretation. • Dual-energy CT of the spine has limited sensitivity for the detection of bone marrow oedema in vertebra with previous surgical intervention.
More Related Videos
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
11:19Dorsal Column Steerability with Dual Parallel Leads using Dedicated Power Sources: A Computational Model
Published on: February 10, 2011
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Marrow Sampling and Transplants
The transplant begins with high doses of chemotherapy and radiation treatment, which aim to destroy...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Improving Translational Accuracy