Detecting demineralization of enamel and cementum after gamma irradiation using radiographic densitometry
Rowida Abdalla1,2, Amr Omar3, Kareem Eid4
1Division of Restorative Dentistry, Department of Oral Health Practice, D632A UK Chandler Hospital, University of Kentucky, Lexington, KY, 40536-0297, USA. Rowida.abdalla@uky.edu.
Abstract:
The purpose of this study was to evaluate the ability of radiographic densitometry in detecting the early demineralization of human enamel and cementum in irradiated and non-irradiated teeth. Sixty extracted teeth were divided into two groups: irradiated group and non-irradiated group. After irradiation, the groups were subjected to demineralization-remineralization (PH) cycling. Radiographic densitometric measurements (gray values) of a selected area of interest in the enamel and in the cementum of each tooth were performed at baseline and after PH cycling. After PH cycling, there was a significant reduction in gray values for both groups. The difference between "baseline" and "after PH cycling" values represents the reduction in the mineral content of the hard tissue, i.e., the demineralization. Results show that the demineralization of irradiated tooth enamel and cementum was significantly higher compared to that of non-irradiated tissues as determined by gray-level values. It is concluded that densitometric measurements by means of digital radiographs allow for the detection of demineralization of enamel and cementum, and can be used successfully for diagnosis of the early carious lesions in patients who received head and neck radiotherapy. This will allow implementation of remineralizing therapy and avoid the risk of progression of radiation caries. Furthermore, it is concluded that gamma irradiation with typical therapeutic doses for head and neck carcinoma is a direct cause of demineralization of tooth enamel and cementum.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...