Related Experiment Video
Updated: Feb 8, 2026

09:51
Laparoscopic Anterior Right Hepatectomy: A Single-Center Experience
Published on: December 4, 2023
1.7K
Correction to: Single lung transplantation for lymphangioleiomyomatosis: a single-center experience in Japan
Hisashi Oishi1, Tatsuaki Watanabe2, Yasushi Matsuda2
1Department of Thoracic Surgery, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryomachi, Aobaku, Sendai, 980-8575, Japan. hisashi.oishi.c7@tohoku.ac.jp.
Surgery Today
|June 28, 2018
Abstract:
In the original publication, Fig. 3 has been incorrectly published. The correct version of Fig. 3 is given in this Correction.
Related Concept Videos
Lung Capacity
56.4K
The air in the lungs is measured in volumes and capacities. Lung volume measures reflect the amount of air taken in, released, or left over after a lung function, like a single inhalation. Lung capacity measures are sums of two or more lung volume measures.
56.4K
Load along a Single Axis
647
In structural engineering, the analysis of beams subjected to varying loads is a critical aspect of understanding the behavior and performance of these structural elements. A common scenario involves a beam subjected to a combination of different load distributions.
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
647
Single Pipe Systems
459
In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
459
Distance Corrections
297
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
297
Power Factor Correction
547
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
547
Angular Momentum: Single Particle
7.8K
Angular momentum is directed perpendicular to the plane of the rotation, and its magnitude depends on the choice of the origin. The perpendicular vector joining the linear momentum vector of an object to the origin is called the “lever arm.” If the lever arm and linear momentum are collinear, then the magnitude of the angular momentum is zero. Therefore, in this case, the object rotates about the origin such that it lies on the rim of the circumference defined by the lever arm...
7.8K

