99mTc-GSA SPECT/CT fusion imaging for hepatectomy candidates with extremely deteriorated ICG value
Tatsuaki Sumiyoshi1, Takehiro Okabayashi2, Yuji Negoro3
1Department of Gastroenterological Surgery, Kochi Health Sciences Center, 2125 Ike, Kochi, Japan. tasu050520@yahoo.co.jp.
Purpose:
The value of indocyanine green (ICG) test is negatively affected in patients with intrahepatic shunt, ICG excretory defect, or jaundice. This study evaluated 99mTc-GSA SPECT/CT fusion imaging for assessing liver function in patients with severely deteriorated ICG values.
Materials And Methods:
Thirteen hepatectomy candidates with ICG retention rates over 40% were retrospectively analyzed. The ICG clearance rate (KICG) and estimated KICG obtained by 99mTc-GSA scintigraphy (KGSA) were used to evaluate preoperative whole liver function. Remnant liver function was assessed using the remnant (rem) KICG (= KICG × volumetric rate) and remKGSA (= KGSA × functional rate) indices; hepatectomy was considered unsafe for values < 0.05. The correlations of remKICG and remKGSA with postoperative mortality and morbidity were also investigated.
Results:
KGSA values were significantly greater than KICG values (median: 0.12 vs. 0.059; p < 0.01); remKGSA values were greater than remKICG values in all patients (median: 0.107 vs. 0.0413; p < 0.01). Hepatectomy was considered unsafe in 70% patients using remKICG, and in none of those using remKGSA; liver failure or postoperative mortality did not occur.
Conclusions:
99mTc-GSA SPECT/CT fusion imaging enables more accurate liver function assessment than the ICG test in patients with severely deteriorated ICG values.
More Related Videos
11:03Robotic Left Hepatectomy using Indocyanine Green Fluorescence Imaging for an Intrahepatic Complex Biliary Cyst
Published on: June 24, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Imaging Studies for Cardiovascular System V: CT
Mortar Joint Deterioration in Masonry
The...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Absolute and Local Extreme Values