Related Experiment Video
Updated: Feb 8, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging
M S Alavi1,2, M A Okhovat3, M Atefi1,2
1Ionizing and Non-Ionizing Radiation Protection Research Center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
Introduction:
With increasing the usage of myocardial perfusion imaging (MPI) for the diagnosis of ischemic heart disease, we aimed to evaluate the side effects of low-dose radiation induced by this technique on blood elements, especially proteins and liver function factors.
Material And Methods:
40 eligible patients (Mean age: 54.62±10.35, 22 female and 18 male), who had referred to the nuclear medicine department for MPI from May till August 2014, were enrolled in the study. A blood sample was taken from each patient just before and 24 hours after the injection of 740Mbq of Tecnetium-99m Methoxy isobutyl isonitrile (99mTc-MIBI) in the rest phase of the MPI in a reference medical laboratory; blood tests included total protein (TP), albumin (Alb), globulin (Glo), aspartate aminotransferase (AST), alanine transaminase (ALT), alkaline phosphatase (ALP), direct bilirubin (D.Bili), total bilirubin (T.Bili), serum iron (SI), total iron bounding capacity (TIBC), Albumin globulin ratioA/G ratio), and complete blood count (CBC).
Results:
Injection of 740Mbq99mTc-MIBI caused a significant increase in serum levels of AST (p= 0.001), ALT (p= 0.001), SI (p= 0.030), TIBC (p= 0.003) and A/G Ratio (p= 0.020). However, following radiotracer injection, a significant decrease was noted in the serum levels of TP (p= 0.002), Alb (p= 0.014), Glo(p= 0.002), ALP (p= 0.001), D.Bili (p= 0.003) and T.Bili (p= 0.000).
Conclusion:
Due to increased usage of MPI, our data highlights the importance of monitoring the clinical and paraclinical effects of the procedure on vital organs and physiological pathways to reduce their adverse effects.
Related Concept Videos
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Biological Effects of Radiation
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Effect of Hepatic Disease on Pharmacokinetics: Drug Dosing and Hepatic Blood Flow