Related Experiment Video
Updated: Feb 8, 2026

Experimental Model of Ligature-Induced Peri-Implantitis in Mice
Published on: May 17, 2024
Profilometric changes of peri-implant tissues over 5 years: A randomized controlled trial comparing a one- and
Vitor Marques Sapata1,2, Ignacio Sanz-Martín1, Christoph H F Hämmerle1
1Clinic of Fixed and Removable Prosthodontics and Dental Material Science, University of Zurich, Zurich, Switzerland.
Objectives:
To assess the profilometric changes of the buccal soft tissues between baseline and 5 years of loading using a one- and two-piece dental implant system.
Materials And Methods:
Sixty patients randomly received dental implants of either a two-piece type (BRA) or a one-piece type (STM). Casts were obtained at baseline (after crown insertion), at the 1-year and at the 5-year follow-up. Stereolithography files were obtained from the casts for digital superimposition. One implant and the contralateral natural tooth were selected for the analysis. Thirty-three patients (BRA = 16; STM = 17) were included. Measurements included changes for crown height (CH) and estimated soft tissue thickness, as well as the profilometric change at the implant and the tooth site. Nonparametric methods were applied for the statistical analyses and medians and quartiles presented.
Results:
The BRA group lost -0.39 mm and the STM group lost -0.40 mm of volume between baseline and the 5-year follow-up at the implant site (p > 0.05). The tooth site lost -0.18 mm (BRA) and -0.12 mm (STM) (p > 0.05). Volume differences between implants and teeth amounted to -0.05 mm (baseline to 1 year) and -0.25 mm (baseline to 5 years) for BRA, while for STM, the values were 0.03 mm (baseline to 1 year) and -0.16 mm (baseline to 5 years). The changes for implant CH at 1 and 5 years of follow-up amounted 0.10 and 0.09 mm (BRA) and to 0.03 and 0.22 mm (STM). The changes in tissue thickness at 1 and 5 years in the BRA group amounted to -0.28 and -0.66 mm at 1 mm, -0.21 and -0.46 mm at 3 mm, and -0.32 and -0.45 mm at 5 mm, respectively. The changes in the STM group amounted to -0.15 and -0.54 mm at 1 mm, -0.24 and -0.48 mm at 3 mm, and -0.32 and -0.57 mm at 5 mm, respectively. No significantly different medians were observed.
Conclusions:
Minimal profilometric and linear changes occurred at implant sites between baseline and 5 years, between implant and tooth sites and between the two implant systems.
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Clinical Trials: Overview
Trial and Error and Algorithm
Clinical Trials
There are four phases in a clinical trial. A phase one...
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Random Error

