Data mining investigation of the association between a limb ballistocardiogram and blood pressure
Peyman Yousefian1, Sungtae Shin1, Azin Mousavi1
1Department of Mechanical Engineering, University of Maryland, College Park, MD, United States of America.
Objective:
To investigate the association between a limb ballistocardiogram (BCG) and blood pressure (BP) based on data mining.
Approach:
During four BP-perturbing interventions, the BCG and reference BP were measured from 23 young, healthy volunteers using a custom-manufactured wristband equipped with a MEMS accelerometer and a commercial continuous BP measurement device. Both timing and amplitude features in the wrist BCG waveform were extracted, and significant features predictive of diastolic (DP) and systolic (SP) BP were selected using stepwise linear regression analysis. The selected features were further compressed using principal component analysis to yield a small set of DP and SP predictors. The association between the predictors thus obtained and BP was investigated by multivariate linear regression analysis.
Main Results:
The predictors exhibited a meaningful association with BP. When three most significant predictors were used for DP and SP, a correlation coefficient of r = 0.75 ± 0.03 (DP) and r = 0.75 ± 0.03 (SP), a root-mean-squared error (RMSE) of 7.4 ± 0.6 mmHg (DP) and 10.3 ± 0.8 mmHg (SP), and a mean absolute error (MAE) of 6.0 ± 0.5 mmHg (DP) and 8.3 ± 0.7 mmHg (SP) were obtained across all interventions (mean ± SE). The association was consistent in all the individual interventions (r ⩾ 0.68, RMSE ⩽ 5.7 mmHg, and MAE ⩽ 4.5 mmHg for DP as well as r ⩾ 0.61, RMSE ⩽ 7.9 mmHg, and MAE ⩽ 6.4 mmHg for SP on the average). The minimum number of requisite predictors for robust yet practically realistic BP monitoring appeared to be three. The association between predictors and BP was maintained even under regularized calibration (r = 0.63 ± 0.05, RMSE = 9.3 ± 0.8 mmHg, and MAE = 7.6 ± 0.7 mmHg for DP as well as r = 0.60 ± 0.05, RMSE = 14.7 ± 1.4 mmHg, and MAE = 11.9 ± 1.1 mmHg for SP (mean ± SE)). The requisite predictors for DP and SP were distinct from each other.
Significance:
The results of this study may provide a viable basis for ultra-convenient BP monitoring based on a limb BCG alone.
Related Concept Videos
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Hypertension and Regulation of Blood Pressure