Related Experiment Video
Updated: Feb 8, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Pump Position Impacts HeartMate II Left Ventricular Assist Device Thrombosis
Ahmet Kilic1, John Ransom2, Simon Maltais3
1From the Department of Surgery, Johns Hopkins Hospital, Baltimore, Maryland.
Optimizing HeartMate II pump position during left ventricular assist device implantation can significantly reduce the risk of pump thrombosis (PT), hemolysis, and other adverse events. Proper device placement is crucial for improved patient outcomes and event-free survival.
Area of Science:
- Cardiovascular Surgery
- Biomedical Engineering
- Medical Device Technology
Background:
- Left ventricular assist devices (LVADs) are critical for end-stage heart failure management.
- Pump thrombosis (PT) remains a significant complication in HeartMate II LVAD recipients.
- Standardized surgical and medical practices may influence PT rates.
Purpose of the Study:
- To evaluate the rate of pump thrombosis (PT) in the PREVENtion of HeartMate II pump Thrombosis through clinical management (PREVENT) study.
- To identify if specific HeartMate II pump positions are associated with adverse clinical outcomes.
- To determine the impact of pump position on event-free survival.
Main Methods:
- Prospective, multicenter study (PREVENT) evaluating HeartMate II LVAD implantation.
- Chest X-rays used to assess pump pocket depth and inflow cannula (IC) angles.
- Categorization of 'extreme pump position' based on IC angle and pocket depth distributions.
- Multivariable analysis to identify independent risk factors for PT.
Main Results:
- Patients with an extreme pump position had a significantly higher risk of confirmed/suspected PT, hemolysis, and elevated lactate dehydrogenase.
- Extreme pump position was an independent risk factor for PT (HR=3.6, p=0.006) in multivariable analysis.
- Pump position significantly impacted event-free survival and adverse events at 6 months.
Conclusions:
- HeartMate II pump position at implantation is a critical factor influencing patient outcomes.
- Avoiding extreme pump positions may reduce the incidence of pump thrombosis and related complications.
- Optimizing device placement is essential for improving survival free of adverse events in LVAD patients.
Related Concept Videos
Venous Thrombosis I: Introduction
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Impact of Groups on Groups
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...