Related Experiment Video
Updated: Feb 8, 2026

A Rat Model of Ventricular Fibrillation and Resuscitation by Conventional Closed-chest Technique
Published on: April 26, 2015
Mean arterial pressure targeted fluid resuscitation may lead to fluid overload: A bleeding-resuscitation animal
Nándor Öveges1, Ildikó László1, Krisztián Tánczos1
1Department of Anesthesiology and Intensive Therapy, University of Szeged, Szeged, Hungary.
Introduction:
Fluid resuscitation is the cornerstone of treatment in hemorrhagic shock. Despite increasing doubts, several guidelines recommend to maintain mean arterial pressure (MAP) >65 mmHg as the most frequent indication of fluid therapy. Our aim was to investigate the effects of a MAP-guided management in a bleeding-resuscitation animal experiment.
Materials And Methods:
After anesthesia and instrumentation (tbsl) animals were bled till the initial stroke volume index dropped by 50% (t0). Fluid replacement was performed in 4 equivalent steps (t1-4) with balanced crystalloid solution to reach the baseline values of MAP. Invasive hemodynamic measurements and blood gas analyses were performed after each step.
Results:
Mean arterial pressure dropped from tbsl to t0 (114±11 vs 76.9±16.9 mmHg, p<0.001) and returned to baseline by t4 (101.4±14.4 mmHg). From tbsl-t0 stroke volume index (SVI), cardiac index (CI) decreased (SVI: 40±8.6 vs 19.3±3.6 ml/m2, p<0.001; CI: 3.4±0.3 vs 1.9±0.3 l/min/m2, p<0.001), pulse pressure variation (PPV) increased (13.2±4.3 vs 22.1±4.3%, p<0.001). There was a decrease in oxygen delivery (464±45 vs 246±26.9 ml/min, p<0.001), central venous oxygen saturation (82.8±5.4 vs 53.6±12.1%, p<0.001) and increase in lactate levels (1.6±0.4 vs 3.5±1.6 mmol/l, p<0.005). SVI, CI and PPV returned to their initial values by t2. To normalize MAP fluid therapy had to be continued till t4, with the total infused volume of 4.5±0.8 l.
Conclusion:
In the current experiment bleeding led to hemorrhagic shock, while MAP remained higher than 65 mmHg. Furthermore, MAP was unable to indicate the normalization of SVI, CI and PPV that resulted in unnecessary fluid administration. Our data give further evidence that MAP may be an inappropriate parameter to follow during fluid resuscitation.
Related Concept Videos
Pressure of Fluids
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Vapor Pressure of Fluid
When a liquid is placed in a closed container with a small air space, and the space is evacuated, vapor molecules will...
Cardiopulmonary Resuscitation I: Adult
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...

