Toward in vivo dosimetry in external beam radiotherapy using x-ray acoustic computed tomography: A soft-tissue
Hao Lei1, Wei Zhang2,3, Ibrahim Oraiqat4
1Department of Mechanical Engineering, University of Michigan, 2300 Hayward Street, Ann Arbor, MI, 48109, USA.
Purpose:
To study, using phantoms made from biological tissues, the feasibility and practical challenges of monitoring the position of the radiation beam and the deposited dose by x-ray acoustic computed tomography (XACT) during external beam radiotherapy delivery.
Material And Methods:
A prototype XACT system with a single immersion ultrasound transducer, which was positioned around the target sample driven by a motor-controlled rotation stage, was used to acquire the x-ray acoustic (XA) signals produced by a medical linear accelerator (Linac) to form an XACT image of the irradiated phantom. To investigate the feasibility of XACT in tracking the position of radiation dose, a large piece of veal liver with embedded fat tissue was imaged and beam misalignments were measured. Next, we explored the sensitivity of XACT in monitoring and quantifying the delivered dose, in which a block of porcine gel was embedded with equally spaced lard cylinders and imaged. The doses on the lard cylinders modulated by physical wedges were quantified from the XACT image and were verified by comparison to measurements from radiochromic films as the gold standard. Then, to simulate how XACT can perform in a targeted tissue in the human body, a porcine gel phantom with lard cylinders covered by different materials (bone, muscle, and air gap, respectively) was also imaged.
Results:
The reconstructed XACT images of the phantoms show congruence with the boundaries of the beam field and the interfaces between the different tissue materials. The beam displacement from the target was tracked properly by the reconstructed XACT images. An intensity difference as small as 2.9% in delivered dose region can be measured from XACT images P = 0.02. The intensities of XACT images were highly correlated to the film measurements with an R2 better than 0.986. The expected variances of dose delivered to different target regions as a result of the difference in attenuation were successfully captured by the XACT images.
Conclusions:
This study validated the feasibility of XACT in accurately obtaining relative dose maps of tissue-mimicking phantoms. XACT offers a practical method for verifying the beam position against the target and quantifying the relative dose delivered to the target during external beam radiotherapy.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Reliability and Validity
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...