A Reproducible Computerized Method for Quantitation of Capillary Density using Nailfold Capillaroscopy
Published on: October 27, 2015
Image enhancement effect on inter and intra-observer reliability of nailfold capillary assessment
Abdolamir Karbalaie1, Mahnaz Etehadtavakol2, Farhad Abtahi3
1School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Stockholm, Sweden.
Background:
Nailfold capillaroscopy (NC) is a diagnostic imaging technique that is used to assess the blood capillary network in the nailfold area. NC is routinely used for patients with microcirculation problems, such as systemic sclerosis and other connective tissue diseases. Experts commonly use subjective evaluation as a reference point in images of nailfold video capillaroscopy, so it is important to reduce the inherent ambiguities in human judgment and diagnosis. Image quality is an important factor that affects measurement error and assessment time of NC images.
Objective:
In this study, a new image enhancement technique was introduced and evaluated subjectively.
Methods:
In total, 475 nailfold video capillaroscopy images from 18 healthy subjects and 41 systemic lupus erythematosus patients were used. The images were randomly divided into two sets, one each with 275 and 200. Eight independent observers who were familiar with the capillaroscopy technique participated in this study. The set of 275 images was evaluated by three observers with the forced-choice pairwise comparison method. Elliptic broken line (EBL) was used to count the number of capillaries. The intra- and inter-observer reliability of the original and enhanced images was evaluated on 200 images by five observers.
Result:
Except for eight images, all observers preferred the enhanced images in the visual quality comparison method. The intra-class correlation coefficient (ICC) of intra- and inter-observer reliability increased from 0.76-0.84 to 0.82-0.89, respectively, when using the enhancement method.
Conclusion:
By improving the image quality, more capillary details will be visible, and an observer can document more details that may not be visible in the original image and can do so more efficiently.
Related Concept Videos
Naturalistic Observations
Reliability and Validity
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Capillary Exchange
Distribution Reliability and Automation
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...