Related Experiment Video
Updated: Feb 8, 2026

A Finite Element Approach for Locating the Center of Resistance of Maxillary Teeth
Published on: April 8, 2020
Evaluation of Effect of Connector Designs in Implant Tooth-supported Fixed Partial Denture: A Two-dimensional Finite
Srinivasa Gowda1, Dilip D Quadras2, Rajeet S Sesappa3
1Department of Prosthodontics, Armed Forces Medical College Maharashtra University of Health Sciences, Pune, Maharashtra India, Phone: +919049866969,
Aim:
The aim of this study was to evaluate the effect of connector designs on scale and distribution pattern of the stress generated in the supporting bone of implant tooth-supported three-unit fixed partial denture in distal extension situation.
Materials And Methods:
Three-unit fixed partial denture geometric models with implant abutment in second molar, pontic in first molar, and second premolar as mesial abutment in distal extension situations were evaluated using a two-dimensional (2D) finite element analysis. Three models were designed and constructed with mesial and distal rigid connectors, mesial nonrigid connector, and distal nonrigid connector respectively, using the software ANSYS, version 10.0 (University Intermediate). The models were analyzed to determine the maximum equivalent von Mises stress at five critical zones (maximum value) under static axial loading (240 N) after meshing and assigning the material properties.
Results:
The maximum stress concentration values at mesial and distal alveolar crest of the implant-supporting bone were 60.59 and 68.57 MPa, respectively, in Model No 1. The high equivalent von Mises stress concentration values at the mesial and distal alveolar crest of the implant-supporting bone were 1.65 and 0.747 MPa with 0.1 mm vertical movement and 7.88 and 9.34 MPa with 0.5 mm vertical movement of the connector respectively, in Model No 2. The high equivalent von Mises stress concentration values at mesial and distal alveolar crest of the implant-supporting bone were 10.45 and 3.43 MPa with 0.1 mm vertical movement and 4.50 and 5.71 MPa with 0.5 mm vertical movement of the connector respectively, in Model No 3.
Conclusion:
In the supporting bone around the implant in Model No 1, the maximum von Mises stress concentrations were displayed in the crestal zones. In the supporting bone around the implant abutment, the von Mises stress concentrations were minimal toward the apical third zone in all the models. The stress concentrations were minimal in the supporting bone around the implant and the natural tooth in the models with nonrigid connector.
Clinical Significance:
When implant is used as distal abutment in three-unit implant tooth-supported fixed partial denture with pontic at first molar in distal extension situation, it is recommended to place the nonrigid connector in the mesial side of the distal implant abutment.
Related Concept Videos
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Dimensional Analysis
Dimensional analysis allows us to analyze and compare physical quantities on a...
Dimensional Analysis
Classification of Elements and Compounds
Compounds are pure substances composed of two or more elements in fixed, definite proportions. Compounds are classified as ionic or molecular (covalent) based on the bonds...
Elements and Compounds
Elements
Elements are classified as atomic or molecular based on the nature of their basic units. They are unique forms of matter with specific chemical and physical properties that cannot break down into smaller substances by ordinary chemical reactions. There...

