Related Experiment Video
Updated: Feb 8, 2026

Surgical Angiogenesis in Porcine Tibial Allotransplantation: A New Large Animal Bone Vascularized Composite Allotransplantation Model
Published on: August 13, 2017
Bioabsorbable screws, whatever the composition, can result in symptomatic intra-osseous tibial tunnel cysts after ACL
Romain Chevallier1, Shahnaz Klouche2,3, Antoine Gerometta1,4
1Clinique du Sport Paris, 36, Boulevard Saint Marcel, 75005, Paris, France.
Purpose:
To describe the clinical results of patients who underwent surgical treatment for a intra-osseous tibial tunnel cyst on a bioabsorbable interference screw following anterior cruciate ligament reconstruction (ACL).
Methods:
This retrospective study included all patients who underwent surgery between 2004 and 2016 for an intra-osseous tibial tunnel cyst on bioabsorbable interference screw following ACL reconstruction. The diagnosis was suggested clinically by pretibial pain at the incision site, sometimes associated with a palpable subcutaneous nodule and then confirmed on MRI. The first stage of surgery included exploratory arthroscopy followed by open excision/curettage of the cyst and then the tunnel was filled. The main criterion for outcome was a clinically normal knee (no pain, 0-120 range of motion, stable, with no effusion) at 6 months of follow-up.
Results:
This series included 53 patients, mean age 35.3 ± 9.9 years old w ith a mean 4.6 ± 3.1 years (between 3.1 months and 19 years) of follow-up after ligament reconstruction. The tibial screw was completely absorbed in 9/53 (17%) of patients, and fragmented in 22/53 (41.5%). At the 6-month follow-up, 42/53 (79.2%) patients had a normal knee, 11/53 (20.8%) persistent pain in the cyst area, 52/53 (98.1%) normal range of motion and 53 (100%) a stable knee. A recurrent cyst developed at 2 years of follow-up in one patient.
Conclusion:
Complete absorption of a bioabsorbable interference screw is long, increasing the risk of developing intra-osseous tibial cysts during this period. The development of new materials with improved absorption properties is needed.
Level Of Evidence:
IV-Retrospective study.
Related Concept Videos
Resultant of a General Distributed Loading
Examples such as load distribution due to wind and load distribution on a bridge illustrate how this concept is used to analyze and design safe, reliable structures under variable loading conditions. Most structures, such as residential buildings, bridges, and towers, are...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Resultant Moment: Scalar Formulation
To determine the resultant moment, the moments caused by all the forces in a system in the x-y plane are considered. Positive moments are typically...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Resultant Moment: Vector Formulation
The resultant moment of a system of forces can be calculated through vector formulation. For example, if we consider...

