Related Experiment Video
Updated: Feb 8, 2026

In situ Subcellular Fractionation of Adherent and Non-adherent Mammalian Cells
Published on: July 23, 2010
Zolpidem and Eszopiclone Pre-medication for PSG: Effects on Staging, Titration, and Adherence
Aaron B Holley1, William A Londeree2, Karen L Sheikh2
1Pulmonary/Sleep and Critical Care Medicine, San Antonio Military Medical Center, Roger Brooke Dr, San Antonio, TX.
Introduction:
The non-benzodiazepine sedative hypnotic (NBSH) eszopiclone improves polysomnography (PSG) quality and continuous positive airway pressure (CPAP) adherence. It is unclear whether zolpidem has the same effect and neither NBSH has been studied in populations with milder forms of obstructive sleep apnea.
Materials And Methods:
We performed a retrospective analysis on patients undergoing level I PSG at our institution. Patients are pre-medicated with NBSHs at the discretion of the sleep physician. We compared PSG/CPAP titration quality and subsequent CPAP adherence for patients receiving NBSHs or no pre-study medication. We adjusted for obstructive sleep apnea pre-test probability (PTP), arousal threshold, and other factors showing differences at baseline.
Results:
Data on 560 patients were analyzed. Mean age and body mass index were 42.2 ± 10.1 and 28.8 ± 4.5, respectively. Median apnea hypopnea index was 12.9 (6.4-25.3), 100 (18.0%) patients had normal studies, 97 (17.3%) were split, and 457 (81.6%) had a respiratory low-arousal threshold. After adjusting for differences at baseline, neither NBSH was associated with sleep efficiency, wake after sleep onset, or total sleep time on PSG. After adjustment, patients receiving eszopiclone had a higher apnea hypopnea index at the final CPAP pressure (β = 14.2; 95% confidence intervals (CI) 7.2-21.2; p < 0.001) and were more likely to have an unacceptable titration (odds ratio (OR) = 6.6; 95% CI 2.0-21.0; p = 0.002). When only split-night studies were examined, there were no differences in any adherence variables across or between categories.
Conclusions:
In a population with predominantly mild obstructive sleep apnea, NBSHs did not improve PSG or CPAP titration quality and did not increase CPAP adherence. There was no difference in effect between eszopiclone and zolpidem.
Related Concept Videos
Titration of a Polyprotic Acid
Acid-Base Titration Curves
For a titration carried out for 25.00 mL of...
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
pre-mRNA Processing
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a “cap” to the 5’ end of the growing transcript. In this process, a 5’ phosphate is replaced by modified guanosine that has a methyl group attached to it (7-Methyl...
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Inhaled Medications

