Related Experiment Video
Updated: Feb 8, 2026

Solid-phase Submonomer Synthesis of Peptoid Polymers and their Self-Assembly into Highly-Ordered Nanosheets
Published on: November 2, 2011
HPLC-MS/MS combined with membrane-protected molecularly imprinted polymer micro-solid-phase extraction for synthetic
Juan Sánchez-González1,2, Sara Odoardi2, Ana María Bermejo3
1Group of Trace Elements, Spectroscopy, and Speciation (GETEE), Health Research Institute of Santiago de Compostela (IDIS), Department of Analytical Chemistry, Nutrition and Bromatology, Faculty of Chemistry, Universidade de Santiago de Compostela, Santiago de Compostela, Spain.
Abstract:
Synthetic cathinones are a type of drug belonging to group of new psychoactive substances (NPSs). The illicit market for these substances is characterized by the continuous introduction to the market of new analogs to evade legislation and to avoid detection. New screening and confirmation assays are therefore needed, mainly in forensic/clinical samples. In the current development, a porous membrane-protected, micro-solid-phase extraction (μ-SPE) has been developed for the assessment of several cathinones in urine. The μ-SPE device consisted of a cone-shaped polypropylene (PP) porous membrane containing the adsorbent (molecularly imprinted polymers, MIPs, synthesized for the first time for this class of drugs). MIPs were prepared using ethylone and 3-methylmethcathinone (3-MMC) as templates, ethylene glycol dimethacrylate (EGDMA) as a functional monomer, divinylbenzene (DVB) as a cross-linker, and 2,2´-azobisisobutyronitrile (AIBN) as an initiator. The prepared ethylone-based MIP and 3-MMC-based MIP have been fully characterized and evaluated as new selective adsorbents for μ-SPE. Cathinones separation/determination was performed by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). Optimum loading conditions (pH 5.0, loading for 4.0 minutes under orbital-horizontal shaking at 200 rpm) and elution conditions [2.0 mL of 75:20:5 heptane/2-propanol/ammonium hydroxide and ultrasounds assistance (37 kHz, 325 W) for 4.0 minutes] were found for ethylone-based MIP. Validation (intra-day and inter-day precision and analytical recovery) showed RSD values lower than 9 and 10% for intra-day and inter-day precision, and within the 88%-101% range for intra-day and inter-day analytical recovery.
More Related Videos
Related Concept Videos
Molecular and Ionic Solids
Molecular Solids
Molecular crystalline solids, such as ice, sucrose (table sugar), and iodine, are solids that are composed of neutral molecules as their constituent units. These molecules are held together by weak intermolecular forces such as London dispersion forces, dipole-dipole interactions, or hydrogen bonds, which...
Imprinting
Genomic Imprinting and Inheritance
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
Molecular Comparison of Gases, Liquids, and Solids
Polymers
Polymers: Defining Molecular Weight
The number average molecular weight (Mn) is the summation of the number...