Related Experiment Video
Updated: Feb 8, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Comparision of Ambu AuraGain™ and LMA® ProSeal in children under controlled ventilation
Reesha Joshi1, Priya Rudingwa1, Pankaj Kundra1
1Department of Anaesthesia and Critical Care, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
Background And Aims:
The LMA ProSeal® is considered a prototype among the second-generation supraglottic airway devices (SAD). The Ambu AuraGain™ is a relatively new, single use, second-generation SAD with a preformed shape. We conducted this study with the aim of comparing the difference in clinical performance between Ambu AuraGain™ and LMA ProSeal® in children receiving controlled ventilation.
Methods:
Ninety-four children, aged between 6 months to 12 years, weighing 5 to 30 kg, belonging to American Society of Anesthesiologists Physical Status I and II, undergoing elective surgical procedures, were randomized into two groups. The primary end-point was oropharyngeal seal pressure, and the secondary parameters were the number of attempts, time of insertion, ease of placement of the device and gastric tube, and fiberoptic visualization of the laryngeal aperture.
Results:
The mean oropharyngeal seal pressure with Ambu AuraGain™ was significantly higher than LMA ProSeal® (23.3 ± 4.6 cmH2O vs 20.6 ± 4.8 cmH2O, P = 0.007, respectively). The ease and success rate for device placement, fiberoptic visualization of the larynx, and complications were comparable. However, the time for insertion in Ambu AuraGain™ group was shorter when compared to LMA ProSeal® group, median (IQR [range]); 12 (10-15) s vs 20 (18-23) s (P < 0.001), respectively. The gastric drain was significantly easier to insert in Ambu AuraGain™ compared to LMA® ProSeal (P = 0.01).
Conclusion:
Our study suggests that Ambu AuraGain™ could be a useful disposable alternative to LMA ProSeal® for securing airway in children.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...