Related Experiment Video
Updated: Feb 8, 2026

Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models
Published on: September 27, 2024
Three-dimensional Locking Plate and Conventional Miniplates in the Treatment of Mandibular Anterior Fractures
Nilima J Budhraja1, Ramakrishna S Shenoi1, Samprati J Badjate1
1Department of Oral and Maxillofacial Surgery, VSPM's Dental College and Research Center, Nagpur, Maharashtra, India.
Context:
Three-dimensional (3D) locking plates has been designed with the hypothesis that this will overcome the disadvantages of both the systems and also advantages of both systems will be combined for the management of mandibular fractures.
Aims:
The purpose of this study was to evaluate the efficacy of 2-mm 3D locking miniplate in the management of anterior mandibular fracture and to compare it with Champy's miniplate.
Settings And Design:
A prospective, randomized, clinical trial was carried out in thirty patients who were divided equally in two groups.
Subjects And Methods:
Group I and Group II patients were treated with 2-mm 3D locking plates and 2-mm standard miniplates, respectively. They were evaluated according to the outcomes of the study, that is, working time, wound dehiscence, infection, segmental mobility, postoperative occlusion, need for postoperative intermaxillary fixation (IMF), and radiological evaluation of reduction and fixation.
Statistical Analysis Used:
Student's t-test and Mann-Whitney test were used to compare the two systems. The data were analyzed using Statistical Package for the Social Science version 14.0. The P value was taken as significant when <0.05 (confidence interval of 95% was taken).
Results:
The mean duration of procedure for Group I was found to be 49.33 min, whereas for Group II was 59.67 min. There was significantly greater pain on day 1 and at 1 week in Group II patients. 6.7% (n = 1) of both groups showed incidence of infection. Postoperative stability was adequate in most cases except in one patient (n = 1) of 3D locking system, which was revealed as postoperative occlusal disharmony, unsatisfactory radiological reduction of the fracture fragments, and the segmental mobility. There was no incidence of wound dehiscence, tooth damage, and nerve damage in either group.
Conclusions:
The result of the study can conclude that there is no major difference between both systems in terms of treatment outcome.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Enolate Mechanism Conventions
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Muscles of the Anterior Neck
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...