Related Experiment Video
Updated: Feb 8, 2026

Fabrication of Nano-engineered Transparent Conducting Oxides by Pulsed Laser Deposition
Published on: February 27, 2013
Depth-Profiling Microanalysis of CoNCN Water-Oxidation Catalyst Using a λ = 46.9 nm Plasma Laser for Nano-Ionization
Rafael Müller1, Ilya Kuznetsov2, Yunieski Arbelo3
1University of Zurich , Department of Chemistry , Winterthurerstrasse 190 , CH-8057 Zurich , Switzerland.
Abstract:
Nanoscale depth profiling analysis of a CoNCN-coated electrode for water oxidation catalysis was carried out using table-top extreme ultraviolet (XUV) laser ablation time-of-flight mass spectrometry. The self-developed laser operates at λ = 46.9 nm and represents factor of 4 reduction in wavelength with respect to the 193 nm excimer laser. The reduction of the wavelength is an alternative approach to the reduction of the pulse duration, to enhance the ablation characteristics and obtain smaller quasi-nondestructive ablation pits. Such a XUV-laser ablation method allowed distinguishing different composite components of the catalyst-Nafion blend, used to modify a screen-printed carbon electrode surface. Chemical information was extracted by fragment assignment and relative amplitude analysis of the mass spectrometry peaks. Pure Nafion and the exposed carbon substrate were compared as references. Material specific fragments were clearly identified by the detected nonoverlapping mass-to-charge peaks of Nafion and CoNCN. Three dimensional mapping of relevant mass peak amplitudes was used to determine the lateral distribution and to generate depth profiles from consecutive laser pulses. Evaluating the profiles of pristine electrodes gave insight into fragmentation behavior of the catalyst in a functional ionomer matrix and comparison of post-catalytic electrodes revealed spots of thin localized Co residues.
More Related Videos
10:47Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization IR-MALDESI
Published on: March 24, 2016
08:51Profiling of Permethylated Mucin O-glycans Using Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry
Published on: June 20, 2025
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Ionization Energy
Mass Spectrometry: Overview