A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging
Published on: June 21, 2017
In Vivo Photoacoustic Detection and Imaging of Peroxynitrite
Xialing Qin1, Fan Li1, Yifan Zhang1
1Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Laboratory of Evolutionary Theranostics, School of Biomedical Engineering, Health Science Center , Shenzhen University , Shenzhen 518060 , China.
Abstract:
Photoacoustic detection is an emerging noninvasive and nonionizing detection technique with the merits of rich contrast, high resolution, and deep tissue penetration, especially for in vivo detection and imaging. Herein, we developed a photoacoustic (PA) molecular imaging probe (denoted as nanonaps) composed of a naphthalocyanine dye and a heptamethine dye as the internal standard with unchanged signals at 860 nm and the sensing component with peroxynitrite (ONOO-) target-decreased signals at 775 nm, respectively. The as-prepared nanonaps displayed high sensitivity and specificity of ONOO- both in vitro and in vivo. The PA860/PA775 ratio was increased as a function of the concentration of ONOO- (0-250 nM). More interestingly, our ratiometric nanonaps could be used for in vivo detection and imaging of ONOO-.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Imaging Studies VII: Vascular Imaging
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...