Can a Brief Training Session Prepare Physician Sonographers of Differing Experience to Measure the Ischiofemoral
Brennan J Boettcher1, John H Hollman2, Jeffrey M Payne2
1Sports Medicine Fellow, Department of Physical Medicine and Rehabilitation, Mayo Clinic College of Medicine and Science, Rochester, MN.
Objective:
The primary aim of this study was to determine the inter- and intrarater reliability of ultrasound (US) measurements of the ischiofemoral space (IFS) following a brief training session. A secondary aim was to determine if reliability correlated with sonographer experience.
Design:
Prospective cohort study.
Setting:
Physical medicine and rehabilitation department within a tertiary care institution.
Participants:
Seven male and 3 female individuals were recruited to serve as models. Nine physician sonographers (3 postgraduate year [PGY]-2 residents, 3 PGY-4 residents, 3 physicians) were recruited to serve as sonographers.
Methods Or Interventions:
Sonographers received a 15-minute educational session on identifying the IFS with US, followed by 20 minutes of practice. Models were then placed in a prone position and secured to prevent hip movement. All operators measured bilateral IFSs in each model twice with a washout period between measurements. Operators were blinded to all measurements.
Main Outcome Measures:
Primary outcomes were inter- and intrarater reliability interclass coefficients (ICCs) of IFS measurements among the groups with different levels of US experience. Secondary outcomes included comparisons of inter- and intrarater reliability ICCs of IFS measurements between groups, and the difference of mean IFS measurements between groups.
Results:
Intrarater reliability ICCs were 0.829, 0.680, and 0.596 for physician, PGY-4, and PGY-2 groups, respectively. Interrater reliability ICCs were 0.722, 0.427, and 0.558 for physician, PGY-4, and PGY-2 groups, respectively. No statistically significant differences in reliability were identified between groups. Mean IFS measurements were 31.2, 33.4, and 34.0 mm for physician, PGY-4, and PGY-2 groups, respectively. Physician measurements were significantly smaller than the PGY-4 and PGY-2 measurements (P < .049 and P < .01).
Conclusions:
Following a brief training session, experienced sonographers demonstrated excellent IFS measurement intrarater reliability, whereas PGY-4 and PGY-2 sonographers demonstrated fair intrarater reliability. All sonographers demonstrated fair interrater reliability.
Level Of Evidence:
II.
Related Concept Videos
Reliability and Validity
The Stanford Prison Experiment
Space Trusses
At the core of a space truss lies the fundamental unit known as the tetrahedron. This structure is composed of six members that form a three-dimensional shape...
State Space Representation
Consider an RLC circuit, a...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...