Related Experiment Video
Updated: Feb 8, 2026

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale
Published on: August 25, 2014
[Chlorination of Naproxen: Removal, Transformation and Risk Assessment]
Xin-Xin Fan1, Er-Deng Du1, Jia-Qi Li1
1School of Environmental & Safety Engineering, Changzhou University, Changzhou 213164, China.
Abstract:
The by-products produced during chlorination of pharmaceutically active compounds (PhACs) have created widespread public concern. Chlorination of a typical PhAC, naproxen (NAP), was studied. NAP chlorination parameters, intermediates identification, chlorination mechanism, and risk assessment during chlorination process have also been discussed. The results showed that NAP chlorination could fit well with the fist-order kinetics. The rate of removal and rate constants of NAP chlorination decreased with increasing initial NAP concentration and ammonium dosage, while these values increased with increasing initial free chlorine concentration. Acidic condition of the solution could significantly promote NAP chlorination. Five intermediates were identified by HPLC-MS/MS, and the mechanism of NAP chlorination was also put forward. Vibrio fischeri toxicity analysis and ESCOAR prediction indicated that higher toxicity intermediates were produced during NAP chlorination, which pose a potential threat to drinking water safety.
More Related Videos
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Radical Substitution: Allylic Chlorination
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Relative Risk
Electrophilic Aromatic Substitution: Chlorination and Bromination of Benzene
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...