Related Experiment Video
Updated: Feb 8, 2026

Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Dynamic contrast-enhanced CT for the assessment of tumour response in malignant pleural mesothelioma: a pilot study
Eyjolfur Gudmundsson1, Zacariah Labby2,3, Christopher M Straus2
1Department of Radiology, The University of Chicago, 5841 South Maryland Avenue, Chicago, IL, 60637, USA. egudmundsson@uchicago.edu.
Objectives:
The aim of this pilot study was to investigate the utility of haemodynamic parameters derived from dynamic contrast-enhanced computed tomography (DCE-CT) scans in the assessment of tumour response to treatment in malignant pleural mesothelioma (MPM) patients.
Methods:
The patient cohort included nine patients undergoing chemotherapy and five patients on observation. Each patient underwent two DCE-CT scans separated by approximately 2 months. The DCE-CT parameters of tissue blood flow (BF) and tissue blood volume (BV) were obtained within the dynamically imaged tumour. Mean relative changes in tumour DCE-CT parameters between scans were compared between the on-treatment and on-observation cohorts. DCE-CT parameter changes were correlated with relative change in tumour bulk evaluated according to the modified RECIST protocol.
Results:
Differing trends in relative change in BF and BV between scans were found between the two patient groups (p = 0.19 and p = 0.06 for BF and BV, respectively). No significant rank correlations were found when comparing relative changes in DCE-CT parameters with relative change in tumour bulk.
Conclusions:
Differing trends in the relative change of BF and BV between patients on treatment and on observation indicate the potential of DCE-CT for the assessment of pharmacodynamic endpoints with respect to treatment in MPM. A future study with a larger patient cohort and unified treatment regimens should be undertaken to confirm the results of this pilot study.
Key Points:
• CT-derived haemodynamic parameters show differing trends between malignant pleural mesothelioma patients on treatment and patients off treatment • Changes in haemodynamic parameters do not correlate with changes in tumour bulk as measured according to the modified RECIST protocol • Differing trends across the two patient groups indicate the potential sensitivity of DCE-CT to assess pharmacodynamic endpoints in the treatment of MPM.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Pleural Effusion I: Introduction
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's...
Pilot and Numeric Relaying
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...