Synthesis and Calibration of Phosphorescent Nanoprobes for Oxygen Imaging in Biological Systems
Published on: March 3, 2010
Using Ultrafast Responsive Phosphorescent Nanoprobe to Visualize Elevated Peroxynitrite In Vitro and In Vivo via
Zejing Chen1, Peng Yan1, Liang Zou1
1Key Laboratory for Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications (NUPT), Nanjing, 210023, P. R. China.
Abstract:
Peroxynitrite (ONOO- ), a potent biological oxidant, which has a short half-life in physiological conditions, is related to many diseases. Accurate peroxynitrite determination with superior selectivity and sensitivity is important for understanding biological roles of peroxynitrite in different health and disease tissues. Autofluorescence is an inevitable interference in luminescence biodetection and bioimaging, which often reduces signal-to-noise ratio during detection. In this work, a phosphorescent peroxynitrite nanoprobe (MSN-ONOO) which displays two emission bands is prepared by immobilizing two long-lived phosphorescent iridium(III) complexes that are peroxynitrite-activable and -inert, respectively, into water-dispersible mesoporous silica nanoparticles. Owing to the fast response rate, excellent sensitivity and outstanding selectivity of the nanoprobe toward peroxynitrite, it is further used for peroxynitrite determination in vitro and in vivo via ratiometric photoluminescence imaging. More notably, taking advantage of the long-lived phosphorescence of MSN-ONOO, in vivo elevated peroxynitrite is imaged with diminished autofluorescence interference and improved signal-to-noise ratio via time-resolved photoluminescence imaging. As far as it is known, this is the first time for endogenous peroxynitrite detection in vivo via the time-resolved photoluminescence imaging. Furthermore, the production of peroxynitrite in inflamed tissues is visualized.
More Related Videos
09:57Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
06:08Time-resolved Photophysical Characterization of Triplet-harvesting Organic Compounds at an Oxygen-free Environment Using an iCCD Camera
Published on: December 27, 2018
Related Concept Videos
Photoluminescence: Fluorescence and Phosphorescence
A pair of electrons in a...
Photoluminescence: Applications
Freezing Point Depression and Boiling Point Elevation
The boiling point of a liquid is the temperature at which its vapor pressure is equal to ambient atmospheric pressure. Since the vapor pressure of a solution is lowered due to the presence of nonvolatile solutes, it stands to reason that the solution’s boiling point will subsequently be increased. Vapor pressure increases with temperature, and so a solution will require a higher temperature than will pure solvent to achieve any given vapor pressure, including one...
Variables Affecting Phosphorescence and Fluorescence
Fluorescence and Phosphorescence: Instrumentation
Elevation of Intermediate Points on Vertical Curves