Three dimensional characterisation of chromatography bead internal structure using X-ray computed tomography and
T F Johnson1, J J Bailey2, F Iacoviello2
1Department of Biochemical Engineering, University College London, Bernard Katz, London, WC1E 6BT, United Kingdom.
Abstract:
X-ray computed tomography (CT) and focused ion beam (FIB) microscopy were used to generate three dimensional representations of chromatography beads for quantitative analysis of important physical characteristics including tortuosity factor. Critical-point dried agarose, cellulose and ceramic beads were examined using both methods before digital reconstruction and geometry based analysis for comparison between techniques and materials examined. X-ray 'nano' CT attained a pixel size of 63 nm and 32 nm for respective large field of view and high resolution modes. FIB improved upon this to a 15 nm pixel size for the more rigid ceramic beads but required compromises for the softer agarose and cellulose materials, especially during physical sectioning that was not required for X-ray CT. Digital processing of raw slices was performed using software to produce 3D representations of bead geometry. Porosity, tortuosity factor, surface area to volume ratio and pore diameter were evaluated for each technique and material, with overall averaged simulated tortuosity factors of 1.36, 1.37 and 1.51 for agarose, cellulose and ceramic volumes respectively. Results were compared to existing literature values acquired using established imaging and non-imaging techniques to demonstrate the capability of tomographic approaches used here.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ion-Exchange Chromatography
Lewis Structures of Molecular Compounds and Polyatomic Ions
Imaging Studies III: Computed Tomography
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...