Related Experiment Video
Updated: Feb 8, 2026

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Simultaneous Measurement of Curvature, Strain and Temperature Using a Twin-Core Photonic Crystal Fiber-Based Sensor
Tongtong Zhao1, Shuqin Lou2, Xin Wang3
1School of Electronic and Information Engineering, Beijing Jiaotong University, Beijing 100044, China. 14111024@bjtu.edu.cn.
Abstract:
A novel twin-core photonic crystal fiber-based sensor for simultaneous measurement of curvature, strain and temperature is proposed. The fiber sensor is constructed by splicing the homemade twin-core photonic crystal fiber between two segments of single mode fiber. Affected by the coupling between two cores, the transmission spectrum of the fiber sensor has different wavelength responses to curvature, strain, and temperature. The maximal sensitivities to curvature, strain and temperature are 10.89 nm/m-1, 1.24 pm/με and 73.9 pm/°C, respectively. Simultaneous measurement of curvature, strain and temperature can be achieved by monitoring the wavelength shifts of selected valleys in the transmission spectrum. Contrast experiment based on traditional twin-core fiber is carried out. Experimental results demonstrate that twin-core photonic crystal fiber-based sensor has higher sensitivity and better linearity than traditional twin-core fiber-based sensor.
Related Concept Videos
Measurements of Strain
Degree of Curvature and Radius of Curvature
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Vertebral Column: Regions and Curvature
Regions of the Vertebral Column
In an adult, the spine is subdivided into five regions: the cervical, the thoracic, the lumbar, the sacral, and the coccygeal region. The spine initially develops as a series of 33 vertebrae; after 20 years of age, the nine bones in the sacral region, five sacral, and four coccygeal bones fuse to form...

