Related Experiment Video
Updated: Feb 8, 2026

Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials
Published on: August 13, 2019
Radiographic Comparison of Bovine Bone Substitute Alone Versus Bovine Bone Substitute and Simvastatin for Human
Siamak Yaghobee1, Amir Ali Reza Rasouli Ghahroudi1, Afshin Khorsand1
1Associate Professor, Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran; Department of Periodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
Objectives:
The aim of this study was to compare the efficacy of bovine bone substitute (Compact Bone B. ®) alone versus bovine bone substitute and simvastatin for human maxillary sinus augmentation.
Materials And Methods:
This study was conducted on 16 sinuses in eight patients. Radiographic assessments were done preoperatively (T0), immediately (T1) and at nine months after sinus grafting (T2). Alveolar bone height and density were assessed on cone beam computed tomography (CBCT) scans using Planmeca Romexis™ Imaging Software 2.2.
Results:
The change in alveolar bone height and density between T0, T1 and T2 was significant in both groups. Alveolar bone height (h0, h1, h2) and vertical height of the grafted bone (g1, g2) in three lines (anterior, middle and posterior) were not significantly different between groups. The grafted bone height shrinkage (%) in the anterior, middle and posterior limits of the augmented area were not significantly different between groups. The existing alveolar and grafted bone density increased significantly in both groups between T1 and T2, except for the existing alveolar bone density in the control group. There were no statistically significant differences between the alveolar bone density values obtained in TI and T2 between groups, except for the existing alveolar bone density at T1.
Conclusions:
This study did not show any significant positive effect for simvastatin in maxillary sinus augmentation based on radiographic examination.
Related Concept Videos
Trigonometric Substitution
Rationalizing Substitutions
Diazonium Group Substitution: –OH and –H
Evaluating Limits by Direct Substitution
Stability of Substituted Cyclohexanes
The two chair conformations of cyclohexanes undergo rapid interconversion at room temperature. Both forms have identical energies and stabilities, each comprising equal amounts of the equilibrium mixture. Replacing a hydrogen atom with a functional group makes the two conformations energetically non-equivalent.
For example, in...
Nucleophilic Substitution Reactions
In 1896, the German chemist Paul Walden discovered that he could interconvert pure enantiomeric (+) and (-) malic acids through a series of reactions. This conversion suggested the involvement of optical inversion during the substitution reaction. Further, in 1930, Sir Christopher Ingold described for the first time two different forms of nucleophilic substitution reactions, which are known as SN1 (nucleophilic substitution unimolecular) and SN2 (nucleophilic substitution...