Related Experiment Video
Updated: Feb 8, 2026

4D Microscopy of Yeast
Published on: April 28, 2019
A feasibility study of intrafractional tumor motion estimation based on 4D-CBCT using diaphragm as surrogate
Dingyi Zhou1,2, Hong Quan1, Di Yan2
1Key Laboratory of Artificial Micro- & Nano- structures of Ministry of Education and Center for Electronic Microscopy, School of Physics and Technology, Wuhan University, Wuhan, China.
Purpose:
To investigate the intrafractional stability of the motion relationship between the diaphragm and tumor, as well as the feasibility of using diaphragm motion to estimate lung tumor motion.
Methods:
Eighty-five paired (pre and posttreatment) daily 4D-CBCT images were obtained from 20 lung cancer patients who underwent SBRT. Bony registration was performed between the pre- and post-CBCT images to exclude patient body movement. The end-exhalation phase image of the pre-CBCT image was selected as the reference image. Tumor positions were obtained for each phase image using contour-based translational alignments. Diaphragm positions were obtained by translational alignment of its apex position. A linear intrafraction model was constructed using regression analysis performed between the diaphragm and tumor positions manifested on the pretreatment 4D-CBCT images. By applying this model to posttreatment 4D-CBCT images, the tumor positions were estimated from posttreatment 4D-CBCT diaphragm positions and compared with measured values. A receiver operating characteristic (ROC) test was performed to determine a suitable indicator for predicting the estimate accuracy of the linear model.
Results:
Using the linear model, per-phase position, mean position, and excursion estimation errors were 1.12 ± 0.99 mm, 0.97 ± 0.88 mm, and 0.79 ± 0.67 mm, respectively. Intrafractional per-phase tumor position estimation error, mean position error, and excursion error were within 3 mm 95%, 96%, and 99% of the time, respectively. The residual sum of squares (RSS) determined from pretreatment images achieved the largest prediction power for the tumor position estimation error (discrepancy < 3 mm) with an Area Under ROC Curve (AUC) of 0.92 (P < 0.05).
Conclusion:
Utilizing the relationship between diaphragm and tumor positions on the pretreatment 4D-CBCT image, intrafractional tumor positions were estimated from intrafractional diaphragm positions. The estimation accuracy can be predicted using the RSS obtained from the pretreatment 4D-CBCT image.
Related Concept Videos
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Estimation of k and VD of Aminoglycosides
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Equation of Motion: General Plane motion - Problem Solving
The friction between the roller and the ground is characterized by two coefficients. The static friction coefficient is 0.15, while the kinetic friction coefficient is 0.1. These values are crucial in understanding the interaction between...
Projectile Motion: Example
When we speak of the range (R) of a projectile on...

