Sleep and salivary cortisol in preterm neonates: a clinical, randomized, controlled, crossover study
Fabrícia Magalhães Araújo1, Mavilde da Luz Gonçalves Pedreira1, Ariane Ferreira Machado Avelar1
1Universidade Federal de São Paulo, Escola Paulista de Enfermagem. São Paulo, Brazil.
Insights
Ear protectors did not significantly alter salivary cortisol levels or total sleep time in preterm infants. This study found no relationship between cortisol and sleep duration in the neonatal intermediate care unit.
Area of Science:
- Neonatal care
- Pediatric sleep science
- Endocrinology
Background:
- Preterm neonates experience altered sleep-wake cycles and stress responses.
- Environmental management in neonatal intermediate care units (NICUs) aims to optimize infant well-being.
- Salivary cortisol is a key biomarker for physiological stress in neonates.
Purpose of the Study:
- To investigate the impact of ear protectors on salivary cortisol levels and total sleep time in preterm neonates.
- To assess these effects during different environmental management periods in an NICU.
Main Methods:
- A randomized, controlled, crossover study involving 12 preterm neonates.
- Sleep evaluation utilized polysomnography and unstructured observation.
- Salivary cortisol levels were measured at baseline.
Main Results:
- No statistically significant differences were found in baseline salivary cortisol levels between groups.
- Total sleep time did not differ significantly between the ear protector and control conditions.
- No correlation was observed between baseline cortisol levels and total sleep time.
Conclusions:
- The use of ear protectors in preterm neonates did not demonstrate a significant influence on salivary cortisol levels or total sleep time.
- Findings suggest ear protection may not be a critical factor in modulating stress or sleep in this population under the studied conditions.
Objective:
Analyze the influence of ear protectors on the baseline levels of salivary cortisol and response and total sleep time of preterm neonates during two periods of environmental management of a neonatal intermediate care unit.
Method:
A clinical, randomized, controlled and crossover study conducted with 12 preterm neonates. The use of ear protectors was randomized in two periods. Sleep evaluation was performed using one Alice 5 Polysomnography System and unstructured observation.
Results:
No significant difference was observed between the baseline levels of salivary cortisol and response in preterm neonates from the control and experimental groups, and no statistical significance was observed between the total sleep time of both groups. No relationship was observed between the baseline levels of cortisol and response and total sleep time.
Conclusion:
Ear protectors in preterm neonates did not influence the salivary cortisol level and total sleep time in the studied periods.
Related Concept Videos
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Salivary Glands and Saliva
Aneurysm II: Clinical Manifestations and Diagnostic Studies


