Related Experiment Video
Updated: Feb 8, 2026

Measuring Active and Passive Tameness Separately in Mice
Published on: August 10, 2018
Taming the Strength of Interfacial Interactions via Nanoconfinement
David Nieto Simavilla1, Weide Huang1,2, Caroline Housmans1
1Laboratory of Polymer and Soft Matter Dynamics, Faculté des Sciences, Université libre de Bruxelles (ULB), CP223, Boulevard du Triomphe, Bruxelles 1050, Belgium.
Abstract:
The interaction between two immiscible materials is related to the number of contacts per unit area formed by the two materials. For practical reasons, this information is often parametrized by the interfacial free energy, which is commonly derived via rather cumbersome approaches, where properties of the interface are described by combining surface parameters of the single materials. These combining rules, however, neglect any effect that geometry might have on the strength of the interfacial interaction. In this Article, we demonstrate that the number of contacts at the interface between a thin polymer coating and its supporting substrate is altered upon confinement at the nanoscale level. We show that explicitly considering the effect of nanoconfinement on the interfacial potential allows a quantitative prediction of how sample geometry affects the number of contacts formed at the interface between two materials.
Related Concept Videos
The Equilibrium Binding Constant and Binding Strength
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Interfacial Electrochemical Methods: Overview
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...

