Related Experiment Video
Updated: Feb 8, 2026

Characterization of Electrode Materials for Lithium Ion and Sodium Ion Batteries Using Synchrotron Radiation Techniques
Published on: November 11, 2013
Feasibility study of a candidate reference material for ions in PM2.5: does commutability matter also for inorganic
G Emma1, J Snell2, J Charoud-Got1
1European Commission Joint Research Centre, Retieseweg 111, 2440, Geel, Belgium.
Abstract:
The existing Air Quality Directive 2008/50/EC establishes within the European Union (EU) member states limit values for fine air particulate matter (PM2.5) including the possibility to discount natural sources of pollution when assessing compliance with the legislation. In proving this, EU member states shall determine, amongst others, the rural background concentration of some anions (Cl-, NO3- and SO42-) and cations (Na+, NH4+, K+, Ca2+ and Mg2+). To deliver reliable data and to comply with the data quality objectives of the legislation, environmental control laboratories should use certified reference materials (CRMs) to validate or verify the performance of their analytical methods. Since no CRMs for anions and cations in PM2.5 are presently available, we present the commutability issues encountered during the first attempt to develop such a material. We demonstrate that a dust, collected in a road tunnel and previously used for the production of two CRMs of a PM10-like material, does not behave as an authentic fine particulate matter collected according to EN12341:2014 when measured by an established method proposed by the European Committee for Standardization (CEN/TR 16269:2011). The water-soluble fractions of SO42-, NH4+, K+, Ca2+ and Mg2+ in a PM2.5-like candidate CRM produced from that road tunnel dust are only fully extracted after 3 h of sonication and not after 30 min, as stated in the method. Moreover, we found that the particle size of the test material influenced the extraction yield of K+, Ca2+ and Mg2+, suggesting that these ionic species were incorporated in the core of the particles and inaccessible to the extraction procedure. These particular features make the material unsuitable for the measurements of ions with the CEN method. The difference in the extraction time can be seen as a commutability issue and the candidate CRM should be considered as not commutable with routine samples. This demonstrates that commutability studies should not only be considered for clinical CRMs, but also for inorganic CRMs when they are intended to be used to quantify operationally defined analytes.
Related Concept Videos
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Classifying Matter by State
Physical and Chemical Properties of Matter
What is Matter?
The Atomic Theory of Matter
States of Matter
Scientists have discovered a fourth state of matter, plasma, that occurs naturally in the interiors...

