Related Experiment Video
Updated: Feb 8, 2026

A Novel Technique of Rescuing Capsulorhexis Radial Tear-out using a Cystotome
Published on: January 16, 2011
PROMIS: a valid and efficient outcomes instrument for patients with ACL tears
Kyle John Hancock1, Natalie Glass2, Chris A Anthony2
1The Department of Orthopedic Surgery and Rehabilitation, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, 01008 JPP, Iowa City, IA 52242, USA. kyle-hancock@uiowa.edu.
The Patient Reported Outcomes Information System Physical Function Computer Adaptive Test (PROMIS PF CAT) strongly correlates with other physical function measures in ACL surgery patients. This PROMIS PF CAT has a low test burden and no floor or ceiling effects.
Area of Science:
- Orthopedics
- Rehabilitation Medicine
- Health Outcomes Research
Background:
- Patient-reported outcomes (PROs) are crucial for assessing physical function after anterior cruciate ligament (ACL) reconstruction.
- Traditional PRO instruments can be lengthy, potentially impacting patient compliance and data quality.
- The Patient Reported Outcomes Information System Physical Function Computer Adaptive Test (PROMIS PF CAT) offers a potentially more efficient alternative.
Purpose of the Study:
- To compare the PROMIS PF CAT with established knee-specific PROs in a healthy population undergoing ACL surgery.
- To evaluate the correlation strength between PROMIS PF CAT scores and traditional physical function measures.
- To assess the test burden and identify any floor or ceiling effects of the PROMIS PF CAT in this cohort.
Main Methods:
- 100 patients undergoing ACL surgery completed the PROMIS PF CAT, SF-36 PF, KOOS, Marx Scale, and EQ-5D.
- Correlations were categorized as high (≥0.7), high-moderate (0.61-0.69), moderate (0.4-0.6), moderate-weak (0.31-0.39), and weak (≤0.3).
- Floor or ceiling effects were defined as ≥15% of patients reporting the lowest or highest possible score.
Main Results:
- The PROMIS PF CAT demonstrated high correlations with SF-36 PF (r=0.82), EQ-5D (r=-0.70), KOOS ADL (r=0.74), and KOOS Sport (r=0.70).
- No significant floor or ceiling effects were observed for the PROMIS PF CAT (0% of patients).
- The average number of items administered by the PROMIS PF CAT was low (mean 4.2 items).
Conclusions:
- The PROMIS PF CAT is a valid and reliable measure of physical function in patients undergoing ACL surgery.
- It exhibits strong correlations with commonly used PROs, indicating good convergent validity.
- The PROMIS PF CAT presents a low test burden and lacks floor or ceiling effects, making it suitable for this population.
Related Concept Videos
Reliability and Validity
Cardiopulmonary Resuscitation II: ACLS Airway Management
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers
Uncertainty in Measurement: Reading Instruments

