Debris Heterogeneity Across Different Valve Types Captured by a Cerebral Protection System During Transcatheter
Tobias Schmidt1, Martin B Leon2, Roxana Mehran3
1Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany.
Objectives:
This study investigated differences between transcatheter heart valve (THV) types and regarding debris captured by a cerebral embolic protection system (Claret Medical Sentinel, Santa Rosa, California).
Background:
Differences of THV types and cerebral injury after transcatheter aortic valve replacement (TAVR) are not well understood.
Methods:
A total of 246 patients pooled from 2 prospective studies (SENTINEL [Cerebral Protection in Transcatheter Aortic Valve Replacement] trial, N = 100; SENTINEL-H [Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement] trial, N = 146) were included in the analysis. Histopathologic assessment and histomorphometric analyses of debris were compared with THV types. Analyses were differentiated by particle size (≥150, ≥500, and ≥1,000 μm), particle count, total particle area, and maximum of largest dimension. Only commercially available THVs were included: 16% Evolut R (EvR), 15% Lotus, 59% SAPIEN 3 (S3), and 10% SAPIEN XT (XT).
Results:
Particles were captured in 99% of patients. There was a significantly higher amount of debris related to the vascular bed (valve tissue, arterial wall, calcification) in EvR patients compared with S3 patients; 53% of all patients irrespective of valve type had at least 1 particle ≥1 mm. Larger particles (≥500 and ≥1,000 μm) were significantly more frequent in EvR than XT and S3 patients. Lotus patients with particles ≥1,000 μm were significantly more frequent than in S3 patients. Particle count, total particle area, and maximum of largest dimension were significantly higher in both Lotus and EvR patients compared with S3 and XT.
Conclusions:
Debris was captured in 99% of patients, of whom 53% had at least 1 particle of debris >1 mm. The number and size of particles captured during a procedure in which EvR or Lotus THV was used were higher and larger than with a Sapien THV. Regardless, embolic debris, including large particles, is universal across valve types and provides mechanistic support for the potential benefit of using cerebral embolic protection in all TAVR procedures.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...